Offset Through Floor/Ceiling; Glass Doors; Gas Line Installation - Superior CST38MH Installation Instructions Manual

36" wood burning fireplaces
Table of Contents

Advertisement

chImney offseT 30° ThrouGh floor
or ceIlInG
It may be necessary to assemble the chimney
at 30° when passing through the floor or ceil-
ing area. Use the F8FS30-2 firestop spacer as
shown in Figures 41 and 42.
Support the chimney at floor or ceiling penetra-
tion with a FTF8 stabilizer if distance of chimney
below ceiling is 10' (3 m) or more. Maintain 2"
(51 mm) minimum air space to combustibles
from chimney sections. The chimney must
pass vertically through the attic space.
Attic Space
F8FS30-2
Firestop
Spacer
FTF8-S4
Stabilizer
2" (51mm)
Min. Air
Space
10'
(3m) Max.
Figure 41
Room Above
F8FS30-2
Firestop
Spacer
FTF8-S4
2" (51 mm)
Stabilizer
Min. Air
Space
10'
(3m) Max.
Figure 42

Glass doors

The Fireplaces require the use of the standard
glass doors (provided). The use of any other
non-listed door on these fireplaces may result
in a potential fire hazard and is not recom-
mended.
Make a careful inspection of all parts before
installing the doors to ensure they are undam-
aged and complete. There will be two (2) glass
door assemblies for both sides of the CST38MH
fireplace.
Note:
• Design characteristics of a dual-opening
fireplace (whether masonry or factory-built)
may cause it to not draft properly and smoke.
For this reason, glass doors are required with
model CST38MH fireplaces.
• Upper door pivot pins can also be loosened
for adjustment purposes; however, it is easier
to loosen lower pins.
2" (51mm)
Min. Air
Space
If an optional brass or stainless
door was purchased, remove the
plastic protective coating from
the doors before assembly and
installation. failure to remove
the coating before first use will
30 ° Firestop
and Attic Above
result in damage to the finish.
do not touch the doors with your
2" (51mm)
Min. Air
hands while the fireplace is in
Space
use. always use door handles.
doors will become very hot when
fireplace is in use.
30° Firestop
and Room Above
These fireplaces should be oper-
ated only with the doors fully
closed (Figure 44).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
cauTIon
cauTIon
warnInG
Spring Clip
Pivot Pin
Figure 43
Figure 44

Gas lIne InsTallaTIon

The Fireplaces have been approved to accept
a 1/2" (13 mm) gas line for an approved gas
appliance. Always have the appliance installed
by a qualified, licensed plumber in accordance
with all local building codes. The gas line may
enter either end of the fireplace.
cauTIon
Plumbing connections should
only be performed by a quali-
fied, licensed plumber. main
gas supply must be off when
plumbing gas line to fireplace
or performing service.
Upper Door
Guide Track
Roller
Pin
17

Advertisement

Table of Contents
loading

Table of Contents