Superior CFPF-CMN Installation Instructions Manual

Standard series unvented decorative gas fireplaces

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
INSTALLATION
INSTRUCTIONS
Unvented Decorative Gas Fireplaces
P/N 903589 REV. E 02/2004
MODELS
CFST-CMN
CFST-CMP
FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM
HEATERS.
DO NOT BUILD A WOOD FIRE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.
WARNING: DO NOT BURN WOOD OR OTHER MATERIAL IN
THESE APPLIANCES.
CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UN-
LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air Section, Page 3.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appli-
ance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR UNVENTED ROOM
HEATERS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
STANDARD SERIES
CFPF-CMN
CFPF-CMP
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CFPF-CMN and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior CFPF-CMN

  • Page 1 INSTALLATION INSTRUCTIONS STANDARD SERIES Unvented Decorative Gas Fireplaces P/N 903589 REV. E 02/2004 MODELS CFST-CMN CFPF-CMN CFST-CMP CFPF-CMP FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM RETAIN THESE INSTRUCTIONS HEATERS. FOR FUTURE REFERENCE DO NOT BUILD A WOOD FIRE. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL- TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN- JURY OR PROPERTY DAMAGE.
  • Page 2: Table Of Contents

    GENERAL INFORMATION Inventory TABLE OF CONTENTS Unvented Gas Fireplace The CFST and CFPF Series Unvented Room General Information ......page 2 Gas connection fittings Heaters covered in this manual feature ceramic Inventory ......... page 2 Installation and Operating Instructions fiber split logs which glow realistically when the heater is operating.
  • Page 3: Codes

    • The installation must conform with local COMBUSTION AND VENTILATION AIR WARNING: FAILURE TO COMPLY WITH codes or, in the absence of local codes with the THE INSTALLATION AND OPERATING IN- These heaters shall not be installed in a con- National Fuel Gas Code, ANSI Z223.1.
  • Page 4: Location Of Fireplace

    2. Divide the volume of space by 50 ft Your options are: These appliances are uniquely suited for in- determine the maximum BTU/Hr the space stallations requiring a utility shelf positioned can support. a. Rework equations adding the space of ad- directly above the fireplace.
  • Page 5: Preinstallation

    Combustible mantles may be installed above ASSEMBLY STEPS PREINSTALLATION the appliance (as shown in Figure 1 ). The mantle projection may be extended beyond 12" Check that all listed parts have been received. The typical sequence of installation follows, if the height above the firebox opening is in- however, each installation is unique resulting in creased proportionately as detailed by the in- Carefully inspect the heater case and contents...
  • Page 6: Cfst Appliance Specifications

    CFST APPLIANCE SPECIFICATIONS " (140 mm) Left " (1086 mm) View* " " 20" (946 mm) (806 mm) (508 mm) 34" (864 mm) " 4" (114 mm) (102 mm) 24" 40" J Box/Gas Line (610 mm) (1016 mm) Opening (2 Places) 42"...
  • Page 7: Cfpf Appliance Specifications

    CFPF APPLIANCE SPECIFICATIONS " (140 mm) " (1086 mm) 20" 37" 20" (940 mm) (508 mm) (508 mm) 18" 34" (457 mm) (864 mm) 40" Open End (1016 mm) Front View (CFPF) " " (16 mm) (79 mm) " (806 mm) "...
  • Page 8: Connecting Gas Line

    Step 2. Route a " (13 mm) gas line along the Gas Flex Line Kit, Model GFLV left or right side framing ( Figure 9 ). " NPT x " " x " Flare Flare Fitting All appliances have a 3" long "...
  • Page 9 Step 7. Installing the Optional Remote Wall CAUTION: DO NOT CONNECT THE OPTIONAL Step 8. Installing the Optional Forced Air REMOTE SWITCH TO A 120V POWER SUPPLY. Blower Kit Wiring – An electrical outlet box is Switch – The standard millivolt system comes from the factory wired as shown in Figure 12 .
  • Page 10: Electrical Wiring - Optional Blower

    Install the top four twigs beginning with the left twig #5 first ( Figure 16C ). Shift the lower logs OFF/ON Blower Wall Switch left or right as necessary to align the position- ing pins. To Fuse or Circuit Breaker Black Once twig #5 is in position, place the center 120V...
  • Page 11: Flame Appearance

    Flame Appearance In normal operation, at full rate, after 15 min- PORT CLUSTER utes the following flame appearance should be REFER TO THE OPERATING INSTRUCTIONS observed: LOCATED AT THE BACK OF THIS MANUAL BEFORE LIGHTING THE HEATER TO OBSERVE Middle Ember Bed Flame Characteristics – THE FLAMES.
  • Page 12: Optional Equipment

    To light the burner; turn “ON” the optional The appliances covered in this manual are Remote Control Kit remote wall switch (if installed) and rotate the heater rated and produce a great deal of heat. gas valve control knob counterclockwise to Decorative brass trim pieces and hoods may The Model RCK adds the convenience of re- the “ON”...
  • Page 13: Cleaning And Servicing

    18 and 20. All parts should be or- partments, burners and circulating air pas- a " flare to " NPT fitting. The components of dered through your Superior distributor or sageways of the heater be kept clean. this kit are rated for both natural and propane dealer.
  • Page 14: Accessories/Components

    ACCESSORIES AND COMPONENTS Note: Model DAT-6-4 may not be used in conjunction with Model SPK-6. 4-Piece Decorative Brass Louvers Arch Frame Kit -Main Panel VF6-BRLK Forced Air Kit FAB-1100 -Main Panel DAT-6-4 -End Panel VF6-BRLEK -End Panel DAET-6-4 Remote Control Kit Gas Flex Line Kit GFLV Rocker Switch Kit...
  • Page 15: Operating Instructions

    OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This heater has a pilot which must be lit by hand. When •...
  • Page 16 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force. Turn Control Knob to “PILOT” Position Turn Control Knob to “OFF” Position Figure 25 Figure 23 Turn Control Knob to “ON” Position Pilot Location Figure 24 Figure 26...
  • Page 17: Cfst Replacement Parts List

    CFST REPLACEMENT PARTS LIST CFST-CMN CFST-CMP Description Part No. Qty. Part No. Qty. Gas Fireplace Assembly 123071 123072 Bar, Louver (Black) 104951 104951 Hood (Black), Clean Face 108971 108971 Screw 000861 000861 Replacement Glass Panel with Gasket 104852 104852 Door Switch 094468 094468 Gas Valve with Burner Assembly...
  • Page 18: Cfst Replcement Parts

    REPLACEMENT PARTS – CFST NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 19: Cfpf Replacement Parts List

    CFPF REPLACEMENT PARTS LIST CFPF-CMN CFPF-CMP Description Part No. Qty. Part No. Qty. Gas Fireplace Assembly 123073 123074 Bar, Louver (Black) - Main Panel 104951 104951 Bar, Louver (Black) - End Panel 104955 104955 Hood (Black), Clean Face - Main Panel 108971 108971 Hood (Black), Clean Face - End Panel...
  • Page 20: Cfpf Replacement Parts

    REPLACEMENT PARTS – CFPF NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 21: Troubleshooting Guide

    TROUBLESHOOTING GUIDE FOR UNVENTED GAS PRODUCTS OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is A. Igniter electrode positioned wrong. Replace igniter. pressed, there is no spark at ODS/pilot. B. Igniter electrode broken. Replace igniter. C. Igniter electrode not connected to igniter cable. Reconnect igniter cable.
  • Page 22 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 23 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 24: Warranty

    SFC reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement. SUPERIOR FIREPLACE COMPANY NOT RESPONSIBLE FOR WORK DONE WITHOUT WRITTEN CONSENT SFC shall in no event be responsible for any warranty work done without first obtaining SFC’s written consent.