Specification
Cooling
Table 6: Electrical Specifications
Max Power Consumption
Typical Power Consumption
Input Voltage
PSU Connector Type
Inrush Current Maximum (per PSU)
PSU Efficiency
Table 7: Mechanical Specifications
Specification
Shock
Vibration
Weight
Dimensions
System Installation Length
Required Rack Depth
Required Rack Width
1.3 OpenFlex F3100 and E3000 Specification Summary
Non-Operational
N/A
Specification
Non-Operational
20G, 7ms half sine; 3 positive
and 3 negative pulses in each
axis Z and Y. X axis- 15G, 7ms half
sine, 3 positive and 3 negative
pulses
Linear Random: 0.50Grms;
5-500Hz; 10 minutes each axis in
X, Y, and Z
Linear Random: 0.54Grms;
1-200Hz; 60 minutes in Z axis.
Linear Random: 0.80Grms; 2 -
200Hz; 15 minutes in Z axis
Swept Sine: 0.50G, 0 - peak
swept sine; 5 - 500Hz; 1
complete sweep @ 1/2 octave
per minute
68.5 kg / 151.1 lbs.
W: 447.2 mm x L: 828.04 mm x H: 130.9 mm / W: 17.6 in. x L: 32.6 in.
x H: 5.2 in.
778 mm / 30.6 in. from the front rack chassis mounts to the rear of
the system
1000 mm (39.4 in.) of usable rack space, frame to frame
450mm (17.72in.) with 465mm (18.31in.) ± 1.5mm nominal hole
spacing. See EIA-310 Rack Standard
4 Fan Modules (N+1 Supported),
containing two fans per module
Value
1600W
~1400W
200V - 240V
C16
AC line inrush current shall not exceed 40A peak,
for up to one-quarter of the AC cycle after which,
the input current should be no more than the
specified maximum input current.
80 PLUS Platinum
5G, 11ms half sine; 3 positive and
3 negative pulses in each axis-
minimum 6 seconds between
shocks
Linear Random: 0.15 Grms 5-500
Hz 10 minutes each axis in X, Y
and Z
Swept Sine:0.17 G, 0 - peak,
5-500 Hz 0.5 octaves/min,
approx. 13 minutes each axis
1. Overview
Operational
Operational