Download Print this page

Honeywell GKP Manual page 9

Advertisement

9
Disable a user
1
Enter the installer programming mode
Press simultaneously the two buttons "1" and "3" more than 2
1 -
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer's code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
3 - Press "0 to 9" button to select user's number
4 -
Press
5 -
Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played
© 2015 by Honeywell International Inc. All rights reserved.
to disable the user (code and TAG)

Advertisement

loading