Mitsubishi SCM80ZA Manual page 38

Inverter multi-split system room air-conditioner [4 room] (air to air pump type)
Table of Contents

Advertisement

2) Drilling of holes in the wall and fixture of sleeve
¡ The connecting wires may touch the metal inside the wall and cause danger so it is necessary to always use the sleeve.
Indoor side
ø65
¡ Drill a hole with a 65 whole
core drill.
3) Mounting of interconnecting wires (Field wiring)
SKM22, 25, 28, 32, 40 models.
a) Remove the lid.
b) Remove the terminal block cover.
c) Connect the connection wire securely to the terminal block.
1 Connect the connection wire securely to the terminal block. If the
wire is not affixed completely, contact will be poor, and it is danger-
ous as the terminal block may heat up and catch fire.
2 Take care not to confuse the terminal numbers for indoor and outdoor
connections.
3 Affix the connection wire using the wiring clamp.
d) Attach the terminal block cover.
e) Attach the lid.
SKM50 model
a) Open the suction grille, then remove the lid.
b) Remove the wiring clamp.
c) Pass the connecting wire to terminal block from behind of indoor unit.
d) Connect the connecting wire securely to the terminal block.
1 Connect the connection wire securely to the terminal block. If the
wire is not affixed completely, contact will be poor, and it is danger-
ous as the terminal block may heat up and catch fire.
2 Take care not to confuse the terminal numbers for indoor and outdoor
connections.
3 Affix the connection wire using the wiring clamp.
e) Fix the connecting wire by wiring clamp.
f) Attach the lid.
g) Close the suction grille.
Use cables for interconnection wiring to avoid loosening of the wires.
CENELEC code for cables Required field cables.
H05 RNR4G1.5 (Example)
H
Harmonized cable type
05
300/500 volts
R
Natural-and/or synth. rubber wire insulation
N
Polychloroprene rubber conductors insulation
R
Stranded core
4
Number of conductors
G
One conductor of the cable is the earth conductor (yellow/green)
1.5
Section of copper wire (mm
4) Shaping the pipe and drain hose
[Shaping the pipe]
¡ Hold the bottom of the pipe and change its direction
before stretching it and shaping it.
88
Sleeve
Outdoor side
¡ When the pipe is connected at the rear, cut off the lower and the right
side portions of the sleeve collar (as shown by the broken line.)
2
)
[Taping of the exterior]
Pipe
Drain hose
¡ Tape only the portion that runs through the wall.
Sleeve
Wall thickness × 1.5cm
Putty
¡ SKM22, 25, 28, 32, 40 models.
Connecting
Wiring
¡ SKM50 model
Terminal
block
Always tape the crossover wires with the pipe.
: http://splitoff.ru/tehn-doc.html
Inclined plate
Sealing plate
Assembled state
Earth
Wiring
Terminal
Terminal block
Wiring clamp
Terminal
Cover
Block Cover
Lid
Pull the part maked « while
pushing its part in the direction
of allow so as to dismount
it.(Dismount or detach it for
each side).
Suction grille
Connecting wire
Wiring clamp
Lid
Pipe
Screw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Skm25zaSkm22zaSkm40zaSkm50zaSrrm40zaSkm28za ... Show all