Removing The M9037A From The Chassis; Power On Sequence; Power Off Sequence - Keysight Technologies M9037A Startup Manual

Pxie embedded controller
Hide thumbs Also See for M9037A:
Table of Contents

Advertisement

Step 3: Install the M9037A Embedded Controller

Removing the M9037A from the chassis

To remove the M9037A controller, reverse the previous procedure. Execute the
Windows shut down process on the controller first. Then power down the
chassis. Loosen the four captive screws, press down on the ejector/injector
handle and pull outwards to release the module from the backplane. Pull the
module towards you until it is free of the chassis.

Power On Sequence

The M9037A controller, like any PC, will boot with the installed operating system.
Refer to the M9037A User Guide for detailed power on and configuration
sequence information.
The first time the M9037A is powered up, it will prompt you to create a user
password.

Power Off Sequence

As with any PC, Windows-based instruments should not be shutdown by either
turning off the power via an external power source or by pulling the power plug
out from the rear panel. This could corrupt the operating system. The approved
way to shut down the controller is to execute the Windows shutdown process
which shuts down the M9037A controller then turns off the M9018A chassis. If
the M9018A chassis rear panel INHIBIT switch is set to DEF then momentarily
pressing the front panel button shuts down the M9037A safely.
Keysight M9037A PXIe Embedded Controller Startup Guide
Depending on the system configuration, the BIOS may take 90
seconds (or longer) to boot. During this time, the Keysight splash
screen (the Keysight logo) is present and it may appear that
nothing is happening. This is generally caused by the inclusion of
certain devices in the switch fabric (such as RAID controller) that
require a longer time for PCI enumeration.
14