Download Print this page

Start-Up Procedure; Final Checks - Hoshizaki IM-240DME Installation Manual

Modular cuber
Hide thumbs Also See for IM-240DME:

Advertisement

Potable Water
Inlet G3/4
/2-3/4
Nipple
Inlet Hose
Outlet Hose

7. START-UP PROCEDURE

) Disconnect the power supply.
2) Open the water tap.
3) Connect the power supply and energise.
4) The following should occur in sequence:
a) Compressor will start (Hot Gas Valve open).
b) Water Pan will fully open.
c) Water Solenoid will open.
d) Water Pan will start to close (Hot Gas Valve closed).
e) Water Pan fully closed - Pump Motor will start.
f) Water Solenoid will close.
IMPORTANT
. Check the conditions and quality of the ice production.
2. Do not use ice produced in the trial run. It might be
contaminated with foreign matter in the water circuit. Discard
or flush down the drain.

8. FINAL CHECKS

) Is installation free of water leaks?
2) Is the icemaker free from vibration?
3) Are all the panels fixed and secure?
4) Has the user been instructed on correct machine use and handed
the Instruction Manual?
Icemaker
Cooling Water
Inlet Rc/2
Cooling Water
Outlet Rc/2
Drain Outlet R3/4
Fig. 16
5
ENGLISH

Advertisement

loading

This manual is also suitable for:

Im-240xmeIm-240dwmeIm-240xwme