Hoshizaki IM-240DSME Installation Manual
Hoshizaki IM-240DSME Installation Manual

Hoshizaki IM-240DSME Installation Manual

Modular cuber
Hide thumbs Also See for IM-240DSME:

Advertisement

Quick Links

MODULAR CUBER
MACHINE A GLAÇONS MODULAIRE
MODULARER WÜRFELEISBEREITER
IJSBLOKJESMACHINE MET LOSSE OPSLAGBUNKER
FABRICADOR MODULAR DE CUBITOS DE HIELO
CUBETTATRICE MODULARE
INSTALLATION MANUAL
NOTICE D'INSTALLATION
INSTALLATIONSANLEITUNG
INSTALLATIE VOORSCHRIFT
MANUAL DE INSTALACION
MANUALE PER L'INSTALLAZIONE
FOR QUALIFIED INSTALLER ONLY
RESERVE A L'INSTALLATEUR
FÜR DEN INSTALLATEUR
VOOR DE BEVOEGDE INSTALLATEUR
SOLAMENTE PARA INSTALADOR CUALIFICADO
SOLTANTO PER INSTALLATORI QUALIFICATI
IM-240DSME
IM-240XSME
92E1CJ20B (040309)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IM-240DSME and is the answer not in the manual?

Questions and answers

Summary of Contents for Hoshizaki IM-240DSME

  • Page 1 IM-240DSME MODULAR CUBER IM-240XSME MACHINE A GLAÇONS MODULAIRE MODULARER WÜRFELEISBEREITER IJSBLOKJESMACHINE MET LOSSE OPSLAGBUNKER FABRICADOR MODULAR DE CUBITOS DE HIELO CUBETTATRICE MODULARE INSTALLATION MANUAL NOTICE D’INSTALLATION INSTALLATIONSANLEITUNG INSTALLATIE VOORSCHRIFT MANUAL DE INSTALACION MANUALE PER L’INSTALLAZIONE FOR QUALIFIED INSTALLER ONLY RESERVE A L’INSTALLATEUR FÜR DEN INSTALLATEUR...
  • Page 2 6. Do not place anything on top of the icemaker or in front of the Louver. Note: . This icemaker needs a Storage Bin. Hoshizaki recommends the following Ice Storage Bins: 7. This icemaker will not work at subfreezing temperatures. To...
  • Page 3 ENGLISH 4) Place the icemaker on the top of the Storage Bin. Be careful not to 6) Before stacking, remove the clear plastic cover on the upper or damage the icemaker frame and the Bin Control Switch. See Fig. 5. middle unit wiring channel.
  • Page 4 Temperatures not within this operating range may affect the production capacity of the icemaker. Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres. * When the Condenser Unit is installed on a roof, a 50 cm height base is recommended to prevent heat reflection and to avoid the Fuses should be rated at 3A and approved to BS 362.
  • Page 5 ENGLISH [c] INSTALLATION As the total precharged refrigerant amount in the icemaker and remote condenser is 2400g, the required refrigerant charge will ) This Condenser Unit is provided with four mounting holes. Secure the Condenser Unit with four bolts. See Fig. 2. 40g x [length of tube run - 0] m Example - If the length of tubing run is 5m (i.e.
  • Page 6 ENGLISH Note: When removing or installing the Nuts on the Access Valves, Note: The space in the Junction Box is limited. Make the hold the flat surfaces of the valve with a spanner as shown connections outside the Junction Box before securing the below.
  • Page 7 ENGLISH 8) The unit will start a freeze cycle in 80 seconds. Icemaker IMPORTANT . Check the conditions and quality of the ice production. 2. Do not use ice produced in the trial run. It might be Potable Water contaminated with foreign matter in the water circuit. Discard Inlet G3/4 or flush down the drain.