Color
!
Insert tubes into ColorQ with line and arrow facing forward.
Eng
!
s
"
" = Shade meter from bright sunlight. Press/Hold button to turn off.
!
If unit should auto-off during testing rinse and fill one tube to Blank and return
to testing.
!
Brush and rinse all tubes promptly after use.
!
Allow tubes to dry before returning to case.
!
Replace reagent caps securely.
!
Use only LaMotte replacement reagents.
!
Es
Insertar el tubo en el ColorQ recto.
!
s
"
" = apartar el aparato de los rayos del sol. Presionar/mantener el botón
para apagar.
!
Si el aparato se auto-apaga durante el test, llenar un tubo para el Blanco y
volver al análisis.
!
Enjuagar y limpiar todos los tubos adecuadamente después del uso.
!
Permitir que los tubos se sequen antes de volver a usarlos.
!
Cerrar correctamente los reactivos.
!
Introduire le ColorQ droit.
Fr
!
s
"
" = Maintenir l'appareil à l'ombre.
Appuyer le bouton off pour l'eteindre.
!
Si l'appareil s'éteint automatiquement refaire
un blanc et reprendre l'analyse.
!
Essuyer et nettoyer tous les tubes
correctement après l'usage.
!
Permettre que les tubes se sechent bien
avant de les réutiliser.
!
Ferrer correctement les reactifs.
!
Utilisez des réactifs LaMotte pour rechanger
uniquement.
WARNING! This set contains chemicals that may be harmful
if misused. Read cautions on individual containers carefully.
Not to be used by children except under adult supervision.
Pro-11
Q
For software version 2.00 or higher
PO Box 329 • Chestertown • Maryland • 21620 • USA
800-344-3100 • 410-778-3100 • 410-778-6394
www.lamotte.com
7/09 62058-V2
Order Code 2058

Advertisement

Table of Contents
loading

Summary of Contents for LaMotte ColorQ Pro-11

  • Page 1 Permettre que les tubes se sechent bien avant de les réutiliser. Ferrer correctement les reactifs. Utilisez des réactifs LaMotte pour rechanger uniquement. WARNING! This set contains chemicals that may be harmful if misused. Read cautions on individual containers carefully.
  • Page 2 “Blank” dans l'appareil. Aller au chlore (FCL). Enlever le tube. * Reagent is a potential health hazard. Read MSDS at www.lamotte.com. * Los reactivos son peligrosos para la salud. Leer MSDS en www.lamotte.com. * Les Reactifs sont dangereux pour la santé. reactivos son peligrosos. Lire MSDS en www.lamotte.com.
  • Page 3 ColorQ Range: 0-10 ppm chlorine, FREE CHLORINE/BROMINE 0-22 ppm bromine fcl / DPD 1A - Code P-6740-G *DPD 1B - Code P-6741-G Color DPD 1A DPD 1B 1. Add 5 drops of and 5 drops of to same tube. 2. Cap and mix. Insert tube into ColorQ. 3.
  • Page 4 TOTAL CHLORINE ColorQ Range: 0-10 ppm chlorine, 0-22 ppm bromine *DPD 3 - Code P-6743-G Color Color 1. Remove cap from reacted FCL tube (Free Chlorine). DPD 3 2. Add 5 drops of to the tube. 3. Cap and mix. Insert tube into ColorQ. 4.
  • Page 5 ColorQ Range: 6.5-8.5 pH - Code 7037-G Color 1. Fill a clean tube to the 5mL line with water sample. 2. Add 5 drops of 3. Cap and mix. Insert tube into ColorQ. 4. Press button to read “PH” pH. Remove tube. Llenar un tubo limpio hasta la línea de los 5 mL con la muestra de agua.
  • Page 6 ALKALINITY ColorQ Range: 0-250 ppm *ALK - Code 7038-G Color 1. Press button to go to “ALY” Total Alkalinity. 2. Fill a clean tube to the 5mL line with water sample. 3. Add 5 drops of 4. Cap and mix. Insert tube into ColorQ. 5.
  • Page 7 CALCIUM HARDNESS ColorQ Range: 0-700 ppm * CH1 - Code 7042-G for use with ver 1.40 or greater CH2 - Code 7041-G Color 1. Press button to go to “CH” Calcium Hardness. 2. Fill a clean tube to the 5mL line with water sample.
  • Page 8 CYANURIC ACID (STABILIZER) ColorQ Range: 0-125 ppm *CYA - Code 6995A-H Color 1. Press button to go to “CYA” Cyanuric Acid. 2. Fill a clean tube to the 5mL line with water sample. 3. Add 1 tablet. Crush with tablet crusher. Cap. 4.
  • Page 9 COPPER ColorQ Range: 0-4 ppm *Copper - Code 3808A-H Color 1. Press button to go to “COP” Copper. 2. Fill a clean tube to the 5mL line with water sample. COP BCA 3. Add 1 tablet. Crush with tablet crusher. Cap. 4.
  • Page 10 IRON ColorQ Range: 0-3 ppm *Ir - Code 3725A-H Color 1. Press button to go to “Ir” Iron. 2. Fill a clean tube to the 5 mL line with water sample. IRON 3. Add 1 Tablet. Crush with tablet crusher. 4.
  • Page 11 BIGUANIDE ColorQ Range: 0-70 ppm Biguanide Test Solution Code 3919-G Color 1. Press button to go to “bi 9” Biguanide. 2. Fill a clean tube to the 5 mL line with water sample. BIGUANIDE TEST SOLUTION 3. Add 5 drops of 4.
  • Page 12 BIGUANIDE SHOCK (PEROXIDE) ColorQ Range: 0-160 ppm b 5 h Biguanide Shock - Code 6930A-J Color 1. Press button to go to “b Sh” Biguanide Shock. 2. Fill a clean tube to the 5 mL line with water sample. SHOCK 3.