Position the right axle brace under the tractor right hand side. Raise the brace up
to the matching mounting holes in the main fame and rear axle housing. Note the
right side brace is installed on outside edge of the main frame and the left side brace
is installed on the inside edge of the main frame. Pictures below show right side
brace installation. Install the clamp plate with capscrews, washers and nuts as
shown in the main frame parts section. Apply Loc-Tite to the threads and torque to
the values noted in the torque chart located in the maintenance section of this
manual.

HYDRAULIC TANK INSTALLATION

Attach the tank mount to the main frame with the hardware shown in the parts
section.
Install all fittings and tubes into tank and tank filter as shown in parts section
illustration. Insert tank sight glass into front side of the tank. Install the temperature
sensor (optional) or pipe plug into the side of the tank.
Place the tank in the mounting bracket on the main fame as shown in the parts
section. Secure the tank in the mounting bracket with the tank strap and nylock nuts.
Install the filter gauge into the filter housing so that it points to the rear of the
tractor and is clearly visible to the operator. The breather cap will be installed after
tank is filled.