IBM Power Series Handbook page 17

Finding parts, locations, and addresses
Hide thumbs Also See for Power Series:
Table of Contents

Advertisement

An example of a logical location code is:
U789C.001.10ABCDE-P3-C31-T2-L23
The first part of the location code (through the T2 label) represents the physical location code for the
resource that communicates with the target resource. The remainder of the logical location code (L23)
represents exactly which resource is indicated.
Location code format
The location code is an alphanumeric string of variable length, consisting of a series of location
identifiers, separated by a dash. An example of a physical location for a fan is Un-A1.
The first position, represented by Un (where n is equal to any string contained between the U and the
hyphen) in the preceding example, is displayed in one of the forms in the following table.
Note: In location codes the U is a constant digit; however, the numbered positions that follow the U are
variables and are dependent on your server. Each column defines the numbers that follow the U in the
beginning of the location code.
Machine type and model number in a location code
Utttt.mmm.sssssss-A1
The leftmost code is always U.
tttt represents the unit type of the enclosure (drawer or
node).
mmm represents the model of the enclosure.
sssssss represents the serial number for the enclosure.
Note: The mmm or ccc number might not be displayed on all location codes for all servers. If the mmm value is not
displayed, the location code is displayed in one of the following forms:
v Utttt.sssssss-A1
v Uffff.sssssss-A1
The location code is hierarchical; that is, each location identifier in the string represents a physical part.
The order (from left to right), in which each identifier is shown, allows you to determine which parts
contain other parts in the string.
The dash (-) separator character represents a relationship between two components in the unit. In the
example of the fan, whose location code is Un-A1, the dash shows that the fan (A1) is contained in the
base unit (or Un). Modules, adapters, cables, and devices are all parts that are plugged into another part.
Their location codes always show that they are plugged into another part as components of the server.
Another example follows: Un-P1-C9 is a memory DIMM (C9) that is plugged into a backplane (P1),
which is inside the unit (Un).
Note: For devices, certain error conditions might cause an IBM i device to display the device location in
®
an AIX
format.
Table 1. Unit type and locations
Unit type (Utttt.mmm)
U8202.E4B or U8205.E6B
Link to location information
8202-E4B or 8205-E6B Locations
Feature codes and sequence numbers in a location code
Uffff.ccc.sssssss-A1
The leftmost code is always U.
ffff represents the feature code of the enclosure (drawer
or node).
ccc represents the sequence number of the enclosure .
sssssss represents the serial number of the enclosure.
Finding parts, locations, and addresses
5

Advertisement

Table of Contents
loading

Table of Contents