Summary of Contents for Helmholz 700-857-8PS01

  • Page 1 Quick Start Guide PROFINET-Switch 8-port, IP67 Version www.helmholz.com...
  • Page 2: Table Of Contents

    Contents 1. Safety instructions 2. Introduction 3. Preparing the PROFINET-Switch 4. Project planning for PROFINET-Switch 5. Setting the port properties 6. Topology detection 7. Assign the PROFINET-Switch a name 8. Media Redundancy Protocol (MRP) 9. Diagnosis and configuration via the web interface 10.
  • Page 3: Safety Instructions

    1. Safety instructions Target audience This description is only intended for trained personnel qualified in control and auto- mation engineering who are familiar with the applicable national standards. For installation, commissioning, and operation of the components, compliance with the instructions and explanations in this operating manual is essential. The specialist person- nel is to ensure that the application or the use of the products described fulfills all safety requirements, including all applicable laws, regulations, provisions, and standards.
  • Page 4: Introduction

    This Quick Start Guide explains the basic settings for the initial commissioning of PROFINET-Switches for use in a PROFINET project. Operation LEDs You can find further information in the manual. You can find this under (see page 18) www.helmholz.com or scan the QR code directly. SCAN QR CODE PROFINET-Switch, TO GET...
  • Page 5: Preparing The Profinet-Switch

    2.1 Connection Following installation, the PROFINET-Switch can be found in the hardware catalog under “PROFINET IO g Other field devices g Network components g Helmholz PN-Switch”. The PROFINET-Switch must be supplied with 24 V DC at the wide range input Add the “PROFINET-Switch 8-port, IP67”...
  • Page 6 By calling up the properties in the device view, you must assign the PROFINET-Switch a unique PROFINET name in the project and check the IP address for plausibility. Important: The real device must later be assigned the same name as in the project. See also Chapter .6 Quick Start Guide PROFINET-Switch 8-port, IP67...
  • Page 7: Setting The Port Properties

    5. Setting the port properties Each port of the PROFINET-Switch can be individually configured. Transfer medium/duplex: “Activate this port for use” The port not being used can be deactivated with this option. Unauthorized access of the network is prevented. “Automatic” setting The port synchronizes itself automatically with the communication partner (10/100 Mbps/as well as half/full duplex).
  • Page 8: Topology Detection

    6. Topology detection The PROFINET-Switch supports the mechanisms for neighborhood detection (LLDP). With this function it is possible to detect the topology of a PROFINET network, or to specify it for purposes of checking for the correct structuring by the configuration. If the topology was prescribed in the configuration, neighboring devices can also be assigned the PROFINET name in the event of the replacement of a device.
  • Page 9: Assign The Profinet-Switch A Name

    If configuration has taken place correctly, the green “RUN” LED should be on and the “BF” and “SF” LEDs off. Alternatively, the free “IPset” software can be used. Please download the software file under www.helmholz.com or scan the QR code. SCAN QR CODE...
  • Page 10: Media Redundancy Protocol (Mrp)

    X1 for the option “Media redundancy role” and the role set to “Client”. Important: If ring wirinig is established without without the MRP roles being configured for all devices involved, this can result in functional disruptions of the PROFINET network! Helmholz TB20-C | PROFINET IO...
  • Page 11: Diagnosis And Configuration Via The Web Interface

    9. Diagnosis and configuration via the web interface The web interface is also accessible via the IP address assigned to the PROFINET-Switch in the PROFINET network. When the web interface is first called up, the password of the “admin” user is the serial number of the device. The serial number is printed on the right housing side part (e.g.
  • Page 12 One goes to the system view following entry of the new password: Note: If the PROFINET-Switch is configured and used in a PROFINET network, settings in the web interface are only to be viewed as a diagnosis. A reconfiguration of PROFINET-related settings (Port Status, LLDP, DCP, Ring Redundancy) is then not possible in the web interface. Quick Start Guide PROFINET-Switch 8-port, IP67...
  • Page 13: Switch Diagnosis And Settings

    10. Switch diagnosis and settings Extensive information and settings for the function of the switch are accessible in the Switch menu. Quick Start Guide PROFINET-Switch 8-port, IP67...
  • Page 14: Port Mirroring

    11. Port mirroring In order to be able to carry out frame analyses or recordings, Port Mirroring can be activated in the PROFINET-Switch. With Port Mirroring, the frame transfer from one “Mirrored Port” to the “Monitor Port” is completely mirrored, on which an analysis PC can then record everything. 12.
  • Page 15: Agents

    13. Agents In order to already be able to view basic information about the switch at the start website, before or without having logged in, the option “System Status Without Login” can be selected. With “Web Session Timeout”, it can be defined whether an automatic logout should take place in the event of inactivity at the website for security reasons. 14.
  • Page 16: Setting The Time

    15. Setting the time The PROFINET-Switch contains a system clock for the issuing of logs and alarm messages. This can be set either manually or automatically by an SNTP server. Quick Start Guide PROFINET-Switch 8-port, IP67...
  • Page 17: Resetting To Factory Settings

    A firmware update can be carried out via the web interface. The firmware update file can be selected in the menu “System g Firmware”. The file has the ending “HUF” (Helmholz Update File). Please download the firmware file under www.helmholz.com or scan the QR code.
  • Page 18: Led Status Information

    18. LED status information Flashing light The device starts The device is ready to operate The device has no configuration and/or there is no con- nection with the PROFINET controller A PROFINET diagnosis is available Ethernet LEDs Green (Link) Connected Orange (Act) Networktraffic Note: The LEDs “RUN,”...
  • Page 19: Technical Data

    19. Technical data PROFINET-Switch 8-port, managed, IP67 (700-857-8PS01) Dimensions (D x W x H) 24 x 62 x 190 mm Weight Approx. 410 g PROFINET ports (X1) - Protocol PROFINET IO device as per IEC 61158-6-10 - Physical layer Ethernet...
  • Page 20 Our customers are at the center of everything we do. We welcome all ideas and suggestions. Helmholz GmbH & Co. KG | Hannberger Weg 2 | 91091 Großenseebach | Germany | Phone +49 9135 7380-0 | Fax +49 9135 7380-110 | info@helmholz.de | www.helmholz.com...