14. Installation
Indoor Unit
Step 17 Setting indoor unit addresses and
installation options
Set the indoor unit address and installation option with
remote controller option. Set the each option separately
since you cannot set the ADDRESS setting and indoor unit
installation setting option at the same time. You need to
set twice when setting indoor unit address and installation
option.
Setting an indoor unit address
1 Press the
and
buttons at the same time for more
than 3 seconds and then a Main menu will be displayed.
2 Press the
/
button to select
button to enter a Sub-menu setting screen.
3 Press the
/
button to select
button to enter a Indoor Address setting screen.
5 6
NOTE
• The Main/RMC Address which is currently setting will
flicker.
• Data bit 1 and 2 present Indoor unit main address checking
• Data bit 3 and 4 present Indoor unit main address
setting(outdoor unit reset is needed to set).
• Data bit 5 and 6 present Indoor unit RMC address setting/
checking.
4 Press the
/
button to set the Indoor unit Main/RMC
Address.
5 Press the
button to save and complete the option
setting.
6 Press the
button to exit to normal mode.
and then press
and then press
Data bit
1 2 3 4
NOTE
• Press the
button anytime during setup to exit without
setting.
• Address will not be applied if you don't press
• Setting Main/RMC Address of an Indoor unit is available
only with a master wired remote controller.
Setting an indoor unit installation option
In order to check and set the indoor unit installation option
code use the wired remote controller and follow the
directions below.
1 Press the
and
buttons at the same time for more
than 3 seconds and then a Main menu will be displayed.
2 Press the
/
button to select
button to enter a Sub-menu setting screen.
3 Press the
/
button to select
button to enter a Indoor unit installation option code
setting screen.
NOTE
• The first digit represents the page number and the
remaining five digits are installation option.
• The total option codes are 24 digits. You can set six digits
at a time and it is distinguished by page number (0, 1, 2, 3).
4 Press the
/
button to set the installation option
code in order. Press
SEG1
SEG2
SEG3
0
2
RESERVED
SEG7
SEG8
SEG9
Drain
Use of Hot
1
pump
Coil
SEG13
SEG14
SEG15
External
External
2
control
control
output
SEG19
SEG20
SEG21
Individual
Heating
control of
3
setting
a remote
compensation
controller
button.
and then press
and then press
button to go to the next page.
SEG4
SEG5
Exterior
Central
temperature
control
sensor
SEG10
SEG11
Controller
variables
Use of Heater
for auxiliary
heater
SEG16
SEG17
S-Plasma
Buzzer
ion
SEG22
SEG23
Away
RESERVED
Set OFF
Timer
SEG6
RESERVED
SEG12
RESERVED
SEG18
Number
of hours
using
filter
-
-
53