Figure 5-3. Download Firmware Screen; Download Firmware - Adaptec 1742A User Manual

Eisa-to-fast scsi host adapter
Table of Contents

Advertisement

adaptec

Download Firmware

After selecting Download Firmware, the next screen displays.

Figure 5-3. Download Firmware Screen

Enter the filename of the microcode that you are going to down-
load to the host adapter. Enter standard.hex for standard mode
and enhanced.hex for enhanced mode. The Mode field must be
set to standard to download the standard mode microcode, and
enhanced to download enhanced mode firmware. The Mode field
can be toggled by selecting the field and pressing the + or - keys.