Download Print this page

DURKOPP ADLER M-TYPE PREMIUM User Training Manual page 35

Advertisement

Exercise: Sewing in Manual Mode, Gap and Gap+
Pre-setting in Manual Mode
• modify the base parameters :
• stitch length 3.8 mm
• thread tension 25%
• sewing foot pressure 5
• sewing foot stroke 3 mm
• modify the other parameters P...
• Thread Trim active On
• Start bartack active (On)
• Number of backward stitches (3 points)
• Number of forward stitches (3 points)
• St.Len.Def – Default stitch length active (On)
• End bartack active (On)
• Number of backward stitches (3 points)
• Number of forward stitches(3 points)
• St.Len.Def – Default stitch length active (On)
• Gap (edge guide): 10 mm
• adjust the auxiliary values:
nd
• 2
stitch length 6.0 mm
nd
• 2
thread tension 30%
nd
• 2
gap (edge guide distance) 20 mm
During Sewing Process
• start sewing
(automatic start bartack)
• activate/deactivate the auxiliary values
nd
activate 2
stitch length
nd
• activate 2
foot stroke
nd
• activate 2
thread tension
nd
• activate 2
gap (gap+)
• deactivate the secondary values
• stop sewing, end of seam (pedal -2)
(automatic end bartack)
35