5. Exit Multi test I/O.
6. Pull up the pressure controller (4) and turn it until the pressure level is
16.2 Setting the transport clamp control
Fig. 132: Setting the transport clamp control
(1) - Pressure gage, left
(2) - Pressure controller, left
Information
The downforce pressure can be set separately for the right and the left
transport clamp depending on the type and thickness of the material.
To set the transport clamp control:
1. Turn the left pressure controller (2) to set the downforce pressure of
2. Turn the right pressure controller (3) to set the downforce pressure of
Important
The safe transport of the sewing material needs to be ensured at all times.
146
If display reads S11+:
• Turn the screw (2) counterclockwise until the display reads S11-.
at 6 bar.
①
②
the transport clamp on the left.
The default setting is 0.5 Mpa = approx. 5 bar.
• Increase pressure: turn counterclockwise
• Reduce pressure: turn clockwise
the transport clamp on the right.
The default setting is 0.5 Mpa = approx. 5 bar.
• Increase pressure: turn counterclockwise
• Reduce pressure: turn clockwise
Pressure supply
(3) - Pressure controller, right
(4) - Pressure gage, right
Service Instructions 745-35-10 D - 00.0 - 10/2017
④
③