3. Insert the locking peg through the hole in the machine arm.
 The locking peg must engage in the slot of the arm shaft crank.
4. Check the position of the needles to the hook tips.
Fig. 39: Setting the needle holder height (2)
(4) - Hex key
(5) - Hole
(6) - Screw
5. Remove the throat plate.
6. Remove the needles from the needle holders (8).
Information
Turning the needle holders requires that the needle bar be disconnected.
7. Use the handwheel to move the needle bars nearly up to the top dead
8. Use a hex key (4) to press down and hold the switch rod through
9. Continue to turn the handwheel.
 The depressed switch rod switches the needle bar off.
10. Relieve the switch rod.
11. Insert the measuring pin (2) into the needle holder as far as it will go.
12. Tighten the screw (7).
13. Place the measuring bridge (3) on the throat plate support.
14. Turn the needle bar to the loop stroke position and lock it in place using
 It should be possible to slide the measuring bridge under the
48
center.
the hole (5).
the locking peg.
measuring pin (2) with as little play as possible.
(7) - Screw
(8) - Needle holder
Service Instructions 745-35-10 D - 00.0 - 10/2017
Machine head