5. Exit Multi test I/O.
6. Pull up the pressure controller (4) and turn it until the pressure level is
15.2 Setting the transport clamp control
Fig. 150: Setting the transport clamp control
(1) - Pressure gage, left
(2) - Pressure controller, left
Information
The downforce pressure can be adjusted separately for the right and the
left transport clamp depending on the type and thickness of the material.
To adjust the transport clamp control:
1. Turn the left pressure controller (2) to adjust the downforce pressure
2. Turn the right pressure controller (3) to adjust the downforce pressure
Important
The safe transport of the sewing material needs to be ensured at all times.
168
If display reads S11+:
• Turn the screw (2) counterclockwise until the display reads S11-.
at 6 bar.
①
②
of the transport clamp on the left.
The default setting is 0.5 Mpa = approx. 5 bar.
• Increase pressure: turn counterclockwise
• Reduce pressure: turn clockwise
of the transport clamp on the right.
The default setting is 0.5 Mpa = approx. 5 bar.
• Increase pressure: turn counterclockwise
• Reduce pressure: turn clockwise
(3) - Pressure controller, right
(4) - Pressure gage, right
Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Pressure supply
④
③