Programming
To program the loading process:
1. Press the desired button.
The user interface for setting the desired item is displayed.
The display switches to Blowing mode.
Fig. 181: Select blowing mode
Symbols
Service Instructions 745-35-10 D - 00.0 - 10/2017
Select blowing mode
Meaning
Function off
1: Lower pickup folder
2: Blowing ON at flap clamp + folding plate
1: Lower pickup folder
2: Blowing ON at folding plate
3: Blowing ON at flap clamp
1: Lower pickup folder
2: Blowing ON at flap clamp, blowing ON at folding plate for 10 mm
seam path
1: Lower pickup folder, blowing ON at flap clamp + folding plate
207