Installing a BaseIO Card
1.
Reinstall the SSD drives into the correct location on the BaseIO card.
2.
Install the replacement BaseIO card by aligning it with the appropriate slot and pushing down
until it is fully seated.
3.
Secure the BaseIO card with the retaining screw.
4.
Reconnect the cables to the BaseIO card.
5.
Replace the front top cover and secure with the T10 TORX screws.
6.
Slide the chassis into the rack.
You will have to release the latches at the halfway point. Push the lock tab on the left side of
the chassis down, and push the lock tab on the right up to release.
7.
Reconnect the NUMAlink and other cables on the front of the chassis.
8.
Replace the bezel.
9.
Reconnect the power cables on the rear of the chassis.
After BaseIO Card Replacement
Complete the following steps to return the system to operational:
1.
Connect power to the system.
2.
Run the
rmc> nl7cfg
Recable and run the utility again if necessary.
3.
Have the customer boot the operating system.
4.
Modify the
a.
b.
c.
5.
Run
rmc> uv3dmp
6.
Run
•
•
7.
Have the customer restart the SAP HANA database.
007-6442-002
utility from the RMC to verify cabling.
nl7cfg
/etc/udev/rules.d/70-persistent-net.rules
Change the eth0 entry to match the new MAC address listed in the eth1 entry.
Remove the eth1 entry that was created.
Reboot the system.
to log the hardware status after replacing the part:
uv3dmp
to verify the performance and configuration for the system:
sgi_health_check
For an SAP HANA appliance, use:
For an SAP HANA TDI system, use:
Replacing a BaseIO Card in an SGI® UV™ 300H Server
sgi_health_check -f
sgi_health_check -t
file:
3
Need help?
Do you have a question about the UV 300H and is the answer not in the manual?
Questions and answers