4 Checking Hardware Installation

4a

Checking device installation

Check Item
Controller
 The device sits stably on the guide rails
enclosure
without displacement.
 Screws are properly secured.
Disk enclosure
4b

Checking cable connections

Check Item
Ground cable, optical
fiber cable, mini SAS HD
electrical cable/optical
cable, network cable,
and serial cable
AC power cable
DC power cable

5 Powering On the Storage System

NOTICE
 To avoid electric shock, do not wear an ESD wrist strap when the storage system is powering on.
 Do not change cable connections between enclosures after power-on. Otherwise the storage system may
malfunction.
The power-on of the storage system takes 15 to 30 minutes. When the power indicator on the controller enclosure no longer
blinks, the power-on is completed.
 Follow the correct power-on sequence of the storage system: Turn on the external power supplies to each
device (disk enclosures first and then controller enclosures). → Press the power buttons on the controller
enclosures. → Power on the switch. → Power on the application servers.
 Follow the correct power-off sequence of the storage system: Stop host services. → Press and hold down the
power buttons (typically for five seconds) on the controller enclosures until the system is powered off. →
Disconnect the controller enclosures and the disk enclosures from their power supplies.
Switching on external power supplies
5a
Turn on external power supplies in the following sequence:
disk enclosures → controller enclosures → switches (for a SAN) → application servers.
Scenario 1 Turning on the switches of the power
distribution box
Normal
Normal
The cable is fully inserted and secured.
 The AC power cables for each controller
enclosure or disk enclosure are connected to
two separate power supplies for redundancy.
 The AC power cables are secured with
plastic buckles.
The OT terminal of the black cable
connects to the RTN (+) terminal and the
OT terminal of the blue cable connects to
the NEG (-) terminal.
Rear
Front
 The device slants or cannot be detected.
 Screws are loose or have fallen off.
The cable is loose or disconnected.
 The AC power cables for each controller
enclosure or disk enclosure are
connected to the same power supply.
 The AC power cables are not secured
with plastic buckles.
The OT terminal of the blue cable
connects to the RTN (+) terminal and
the OT terminal of the black cable
connects to the NEG (-) terminal.
Scenario 2 Turning on the switch of the PDU