During overhead installation the projector must be always secured by a safety rope which is designed
to hold the twelvefold weight of the device. Only safety ropes with quick-release safety fastener
elements may be used. Hang up the safety rope in the hole of the mounting bracket. Direct the rope
over the truss or an appropriate fastening point. Hang up the end in the fastening element and tighten
the locking nut.
The maximum falling distance may not exceed 20 cm.
A safety rope once exposed to falling load or damaged may not be used furthermore.
Adjust the inclination with the mounting bracket and tighten the locking screws firmly.
Connection to the grid
Danger!
Contact the authorized specialized trade for connection to the electric supply.
Do not carry it out yourself.
Connect the device via mains plug to the grid.
If the device is directly connected to the local electricity grid, the installation of a separator with at least
a 3 mm contact hole for each pole is necessary.
The connection is exclusively permitted for electrical installation which complies with the VDE-
regulations DIN VDE 0100. Indoor installation must be equipped with an earth leakage circuit breaker
(RCD) with 30 mA rated current.
Danger!
An expert must check the installation before initial start-up.
A I R B A S E 8 5 0 M K 2
9 / 15