Functions, jumpers and displays

Functions, jumpers and displays

Installer mode

The sounder's installer mode prevents the sounder and the flashing light from being activated
when the cover is opened.
Installer mode is activated when installer mode is called up on the alarm panel and is deactivated
when installer mode is exited.
When installer mode is activated, the two comfort LEDs are continuously on for several minutes.

Jumpers and battery connector

Note:
Changes to jumpers are only applied if the sounder's tamper switch is open.
However, if you have closed the tamper switch for testing purposes, a change to the jumpers will
not have any effect.
Figure 3: Jumpers and connectors
Key:
Set Conf
Jumper for activating confirmation in the event of the alarm panel being activated/de-
activated
Jam Det
Jumper for activating jamming monitoring
Tone
Jumper for selecting the desired normal alarm tone
Time
Jumper for selecting the siren duration
Bat A/Bat B
Battery connectors
Set Conf
Activates or deactivates the flashing light/beep acknowledgement.
If the flashing light is to flash briefly when the system is armed or disarmed, use the alarm
panel to enable the "Strobe on Set" or "Strobe on Unset" option in the relevant partition.
If the sounder is to beep briefly when the system is armed or disarmed, use the alarm panel
to enable the "Beep on Set" or "Beep on Unset" option in the relevant partition.
Installer Mode -> Partitions -> Partition x -> All set / Part set
Jumper connected = flashing light/beep activated
Jumper open = flashing light/beep deactivated