Mounting The Wire Guide - Abicor Binzel ABIMIG 0 Series Operating Instructions Manual

Hide thumbs Also See for ABIMIG 0 Series:
Table of Contents

Advertisement

Available languages

Available languages

5 Putting into operation
1
Transition piece
2
Counter nut
Fig. 1
Equipping the torch ABIMIG
1
Transition piece
2
Tip adaptor
Fig. 2
Equipping the torchABIMIG

5.2 Mounting the wire guide

EN - 10
Wear parts for ABIMIG
5
4
3
Tip adaptor
4
Contact tip
NOTICE
• The counter nut and the tip adaptor are attached to the torch neck by
means of a left-handed thread.
• The left-handed thread is marked at the tip adapter, at the counter nut
and at the torch neck with a groove.
• During mounting screw the tip adapter tightly against the torch neck.
Then screw the counter nut tightly against the tip adaptor, in order to
secure a tight connection.
Wear parts for ABIMIG
4
3
NOTICE
• The tip adapter is fastened to the torch neck by means of a right-handed
thread.
• During mounting screw the tip adapter tightly against the torch neck.
NOTICE
• Only use gas-tight, plastic-insulated wire guides to ensure a secure
shielding gas cover and a defined current contact.
• Bare liners give rise to a loss of shielding gas.
®
XX0
3
2
®
XX0
®
XX5/XX7
2
3
Contact tip
4
Gas nozzle
®
XX5/XX7
®
ABIMIG
XX0/XX5
1
5
Gas nozzle
1

Hide quick links: