SC847E1C/2C JBOD Chassis Manual
E-10 SC847
Cabling
SAS3 I
C Cabling in the SC847B Chassis
2
Use the diagram below to connect the I
the CSE-PTJBOD-CB3 is cabled correctly according to the table below.
Jumper
Pins 1-2: SAS3 setting (Default)
JP5
Pins 2-3: SAS2 and SC847D setting
When enabling SAS2/SAS3 functionality, use the connectors on the upper left of
the CSE-PTJBOD-CB3 power board (See Page 2-4) and set the JP5 jumper as
shown in the chart above.
When an SC847D chassis is being used, use the connectors along the bottom
edge fo the power board (See Page 2-4) and set the JP5 jumper as shown in the
chart above.
JP1
JP3
CSE-PTJBOD-CB3
Figure E-7: SAS3 I
Jumper Settings
CBL-CDAT-0601
CBL-CDAT-0601
C Cabling in the SC847B Chassis
2
C cabling. Ensure that the JP5 jumper on
2
Setting
Front Backplane BPN-SAS3-
846EL1/EL2 Connected to the
Primary I
Rear Backplane
BPN-SAS3-826EL1/EL2
Connected to the Primary I
Connector (I2C4)
E-12
C Connector (I2C0)
2
C
2