Dräger Polytron SE Ex PR NPT1 DD Instructions For Use Manual page 44

Sensing heads with controller units polytron and regard
Hide thumbs Also See for Polytron SE Ex PR NPT1 DD:
Table of Contents

Advertisement

Available languages

Available languages

Sensing Head Polytron SE Ex HT M DD
Operating parameters
- constant sensor current
- voltage at test points
Enclosure protection acc. to EN 60 529:
Device description acc. to 94/9/EG:
1. DrägerSensor HT M DD:
2. Enclosure (junction box):
3. Cable gland:
Environmental Conditions
Operation:
Storage (also for replacement sensors)
1) Year of construction is coded by the third capital letter of the serial number on
the type plate: Z = 2008, A = 2009, B = 2010, C = 2011, D = 2012, E = 2013, etc.
Example: Serial number ARBH-0054, the 3rd capital letter is B, so the year of construction is 2010.
44
255 / 270 mA
561 / 594 mV (Controller unit Polytron SE Ex)
IP 66
Dräger Safety, D-23560 Lübeck, Germany
Polytron SE Ex HT M DD
year of construction by serial number
Dräger Safety, D-23560 Lübeck, Germany
DrägerSensor Ex HT M
II 2G Ex d IIC T6/T5/T4/T3
II 2D Ex tD A21 IP 6x T130/T195°C
DEMKO 09 ATEX 0924202 X
CE 0158, year of construction by serial number
Flameproof Electrical Enclosures Ltd., Oldbury, England
Typ Range 2000
II 2G Ex e II T3
II 2D Ex tD A21 IP 66 T200°C
SIRA 06 ATEX 3153
CE 0518, year of construction
Peppers Cable Glands Ltd., Surrey GU15 3BT, UK
Typ A3LF
II 2G Ex e II
II 2D tD A21 IP68
SIRA 01 ATEX 1272X
Temperature ranges see "Ambient Temperature and
Temperature Classes" on page 27.
800 to 1100 hPa,
5 to 95 % rel. humidity, non-condensing
-40 to +65 °C
700 to 1300 hPa
10 to 90 % rel. humidity, non-condensing
storage time unlimited
1)
1)