PA-3 Power Adapter (50 Hz/Oil-Filled)
PA-3 Power Adapter (50 Hz)
Specifications
Minimum Load
Maximum
25 VA
NOTE A: Load regulation of +10% to -5% is valid for 3-step CCR over 4.7−6.7 A.
B: Primary leads are 30 inches (76.20 cm) long. Secondary leads are 49 inches (124.46 cm) long.
2001 Siemens Airfield Solutions, Incorporated
All rights reserved
This subsection describes the specifications for the Siemens Airfield
Solutions PA-3 power adapter (50 Hz).
Load on CCR for Fully Loaded PA-3 Power Adapter (50 Hz)
Refer to Table 4 for PA-3 power adapter (50 Hz) CCR load.
PA-3 Power Adapter (50 Hz)Technical Features
Refer to Table 5. This subsection describes technical features of the PA-3
power adapter (50 Hz).
NOTE: The portion of the VA load on the CCR due to the power adapter
should be no more than 50%.
Table 5. PA-3 Power Adapter (50 Hz) Technical Features
Load Regulation
Load
(No Load to Full
Load)
300 VA
+3% to -3%
Construction
The PA-3 power adapter (50 Hz) is watertight for direct earth burial, surface
installation, or installation in an L-867 base (16-inch- [40.64-cm-] diameter
base with a minimum height of 24 inches [50.8 cm]).
Environmental Conditions
Refer to Table 6 for environmental conditions.
Temperature Range
-55 to +55 °C (-67 to +131 °F)
Table 4. PA-3 Power Adapter (50 Hz) CCR Load
Step
B1
B3
B5
Input Current
Output Voltage
Range
2.72−6.7 A
Table 6. Environmental Conditions
Humidity
0 to 100%
96A0260B
Issued 5/01
Description
Load
375 W
590 W
1140 W
Leads
Single Phase
60 Hz
120 Vac
2 primary
1 secondary
Altitude
Sea level to 10,000 feet
(3,000 m)
Note
B