The grinder produces an abnormal noise.
There is some water or coffee under the
appliance.
The appliance did not output any coffee.
You used ground coffee instead of coffee
beans.
The grind fineness setting knob is hard to
turn.
Some water or steam abnormally comes
out of the steam nozzle.
The grind fineness setting knob is hard to
turn.
Some water or steam abnormally comes
out of the steam nozzle.
The steam outlet of your cappuccino
system seems to be partially or completely
blocked.
Some ground coffee is found in the drip
tray.
After having emptied the coffee grounds
collector tray, the warning message
continues to be displayed.
After having filled the water reservoir, the
warning message continues to be displayed
on-screen
The machine is not requesting any
descaling.
Foreign bodies are present in the grinder.
The drip tray has overflowed: empty it and clean the coffee grounds
collector tray. Check the proper positioning of the drip tray.
Do not remove the reservoir before the end of the cycle.
An incident was detected during preparation.
The appliance has automatically reset itself and is ready for a
new cycle.
Using your vacuum cleaner, vacuum the pre-ground coffee
contained in the bean reservoir.
An incident was detected during preparation.
The appliance has automatically reset itself and is ready for a
new cycle.
Using your vacuum cleaner, vacuum the pre-ground coffee
contained in the bean reservoir.
Only modify the setting of the grinder when it is in operation.
Foreign bodies are present in the grinder: contact the KRUPS
customer service department.
In the case of repeated operation, a few drops may flow out of
the steam nozzle.
Start the cappuccino system's rinse cycle to clear out the rest of
the deposits.
Clean the steam outlet and check that the nozzle hole is not
obstructed by milk residues or limescale. Use the cleaning
needle if necessary.
This occurs in cases where the coffee grounds fall outside of the
percolation vat: this maintains the cleanliness of the inside of the
machine.
Wait at least 6 seconds before properly reinstalling the coffee
grounds collector tray.
Check the proper positioning of the reservoir in the appliance.
The float in the bottom of the reservoir must move freely. Check
the float and unblock it, if necessary.
The descaling cycle is requested due to a large number of uses
of the steam circuit.