Lincoln Electric POWERTEC i380C ADVANCED Operator's Manual page 20

Hide thumbs Also See for POWERTEC i380C ADVANCED:
Table of Contents

Advertisement

The limits can be set for:
Welding Current
Wire Feed Speed
Welding Voltage
Wave Controls
To set the range:
Enter to the Settings and Configuration Menu.
Use The Right Knob [36] to highlight the "Limits"
icon.
Figure 34.
Press the Right Knob [36] to confirm. List with
available job will be displayed on the screen.
Figure 35.
Use the Right Knob [36] to highlight the job.
Press the Right Knob [36] to confirm selection.
Figure 36.
Use the Right Knob [36] to choose the parameter
which will be changed.
Press the Right Knob [36] to confirm.
Use the Right Knob [36] to change the value. Press
the Right Knob [36] to confirm.
Figure 37. shows the effect of changing the values of
parameters.
English
Press the Button [37] to exit with changes.
Display Configuration
Two Display Configuration are available:
Table 9. Display Configuration
Standard view
Advanced view
To set the Display Configuration:
Access to the Settings and Configuration Menu.
Use the Right Knob [36] to highlight the Display
Configuration icon.
Press the Right Knob [36]. The Display Configuration
Menu is shown on the display.
Use the Right Knob [36] to choose the display
configuration.
18
Figure 37.
Figure 38.
Figure 39.
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powertec i450c advanced

Table of Contents