Nice WIDE S Instructions And Warnings For Installation And Use page 35

Electromechanical road barrier
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS
Description
Product type
Power supply
Maximum power consumption (W)
Maximum current draw (A)
Current draw in stand-by
Minimum opening time (sec)
Rated torque (Nm)
Maximum frequency of operating
cycles/hour (at nominal torque)
Services power output
Emergency power supply
Photovoltaic power supply
Photo test output
Flash output
Courtesy light output
OGI output
Alt input
Step-By-Step input
Open input
Close input
Radio connector
Radio ANTENNA input
Adjustable functions
Use in highly acid, saline or potentially
explosive atmosphere
Operating temperature
Protection rating
Dimensions and weight
Technical specification
WIDES/V1 - WIDESI/V1
Road barrier for residential, public and industrial use
120VC 50/60Hz
300
2
8 mA - 24 Vc
4
100
100
24 Vc maximum current 200 mA (the voltage may vary between 16 V and 33 Vc)
With optional accessory PS324
No
24 Vc maximum current 100 mA (the voltage may vary between 16 V and 33 Vc), connect Nice
photocells exclusively
for 1 ML24 or ML24T flashing light (maximum lamp power = 25 W)
24V lamp output (max 10 W)
for 24 V (max 10 W) indicator light
Configuration of "ALT" input (NC, NO, 8k2, 4k1) with default NC.
For normally open contacts
For normally open contacts
For normally open contacts
SM connector for SMXI, SMXIS, OXI and OXIT receivers
50 Ω for RG58-type cable or similar
using the trimmers (see chapter "Adjusting the trimmers") and micro switches (see chapter"
Programming the control unit")
No
-20°C ÷ 55°C
IP54
280x178x1000h mm; 40 kg
WIDEM/V1 - WIDEMI/V1
300
2,2
3,5
140
300
320x205x1000h mm; 46 kg
Table 14
WIDEL/V1 - WIDELI/V1
360
2,4
5
200
200
420x205x1030h mm; 54 kg
ENGLISH – 35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wide lWide m

Table of Contents