Maintenance; Maintenance Plan; Draining Water - Mann Filter PreLine Series Installation And Maintenance Manual

Prefilters for diesel fuel
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
PreLine

5. Maintenance

Do not disassemble the hand pump!
Maintenance work on the PreLine
filter system should not be carried
out by the driver or garage
workshop personnel.

5.1. Maintenance plan

Activity
Drain water
Change the filter

5.2. Draining water

The water collected must be drained off when
the water collecting tank is full or the filter
must be changed.
Risk of freezing. Drain off the water
before there is a risk of it freezing.
 Switch off the engine to prevent air
getting into the fuel system.
 Connect a hose to the outlet opening.
Place a collecting vessel under the
filter before starting work on it and
dispose of any escaping fuel and/or
water collected in accordance with
the locally applicable environmental
regulations.
 Unscrew the drain plug (Pos.2, Fig. 4) at
the bottom of the water collecting tank
(Pos. 1, Fig. 4) and let the water drain
out.
 Screw the drain plug (Pos.2, Fig. 4) shut
again.
MANN-FILTER
Interval
According to accumulation of water or
before it freezes
Together with the main fuel filter
Comment
Refer to Chapter 5.2
Refer to Chapter 5.4 or filter label
open
Fig. 4
Draining water
close
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Preline 270Preline 420

Table of Contents