Resol DeltaSol Fresh 20 Installation, Operation, Commissioning Manual

Resol DeltaSol Fresh 20 Installation, Operation, Commissioning Manual

Advertisement

Quick Links

DeltaSol Fresh
20
®
Manual for the
specialised craftsman
Installation
Operation
Commissioning
en
Thank you for buying this product.
Manual
Please read this manual carefully to get the best performance from this unit.
www.resol.de
Please keep this manual safe.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DeltaSol Fresh 20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Resol DeltaSol Fresh 20

  • Page 1 DeltaSol Fresh ® Manual for the specialised craftsman Installation Operation Commissioning Thank you for buying this product. Manual Please read this manual carefully to get the best performance from this unit. www.resol.de Please keep this manual safe.
  • Page 2 Safety advice Target group Please pay attention to the following safety advice in order to avoid danger and These instructions are exclusively addressed to authorised skilled personnel. damage to people and property. Only qualified electricians should carry out electrical works. Initial installation must be effected by the system owner or qualified personnel Instructions named by the system owner.
  • Page 3: Table Of Contents

    Contents Overview ....................4 Navigator Installation of the controller .............. 4 Installation page 4 2.1 Overview ........................4 For the electrical connection of the controller, see page 4. 2.2 Outputs ..........................5 Commissioning page 6 2.3 Sensors ...........................5 2.4 Mains connection ......................5 For commissioning the controller after the installation, see page 6.
  • Page 4: Overview

    It must be possible to disconnect the device from the mains at any time. Rated impulse voltage: 2.5 kV Î Install the mains plug such that it is accessible at any time. Data interface: RESOL VBus ® Î If this is not possible, install a switch that can be accessed.
  • Page 5: Outputs

    Outputs The controller is equipped with 2 semi-conductor relays: 100 ... 240 V~ 50-60 Hz IP 20 • Relay 1 (primary pump) is used for power supply of the primary pump: 1 (1) A (100 ... 240) V~ R1 = Output R1 Digital 18 19 R2 1 (1) A (100 ...
  • Page 6: Data Communication / Bus

    1 (1) A (100 ... 240) V~ 17 18 19 Digital R2 1 (1) A (100 ... 240) V~ Sensor Data communication / Bus Adjusting values Temp. Sensor Pt1000 12 13 current value saved VBus PWM VBus terminals ® The controller is equipped with a VBus for data transfer with and energy supply to ®...
  • Page 7: Commissioning Menu

    Commissioning menu forwards (+) selection / adjustment mode backwards (-) The commissioning menu consists of the channels described in the following. Î Connect the device to the mains Language The controller runs an initialisation phase. Î Adjust the desired menu language. When the controller is commissioned or when it is reset, it will run a commission- Date ing menu.
  • Page 8: Menu Structure

    Menu structure Depending on the circulation mode selected, further adjustment channels will ap- date of the last draw-off pear: current date current time Calibration Automatic secondary circuit fl ow rate detection and measurement while the secondary pump is active (for further information about the offset see page Î...
  • Page 9: Selection Menu

    System status Status menu The system status is displayed graphically as a smiley. The different smiley faces have In this menu, status and error messages as well as current measured values are the following meanings: displayed. = System OK = Warning Possible warnings and error messages = Error ⚠...
  • Page 10: Balance Values

    Overrun active Balance values Overrun is active. In this menu, balance values are displayed. Values that are not measured will not T -HW be displayed. Display range: 0 … 100 °C, defective Indication of the hot water temperature in °C. Hygiene rem.
  • Page 11: Settings

    Settings T -Circ. min Note Indication of the minimum temperature at the circulation sensor in °C. The displayed values and options depend on the functions and only ap- pear if these are available for the adjusted system parameters. T -Circ. max Indication of the maximum temperature at the circulation sensor in °C.
  • Page 12: Emergency Operation Menu

    Emergency operation menu The Emergency operation can be used for ensuring the hot water supply in the case of a sensor fault. In this case, the primary pump will permanently run at the adjustable Emergency speed. For this function, the emergency speed must be aligned with the resulting hot water temperature.
  • Page 13 Demand In the "last" display channel, the date of the last calibration is indicated. In the Demand circulation mode, the secondary pump will be activated for the adjustable runtime Circ. run, when a draw-off has been detected. The Toff circ. switch-off temperature serves as the switch-off condition.
  • Page 14 If the temperature at sensor S3 in the secondary circuit exceeds the switch-off temperature, the controller deactivates the secondary pump. This switch-off condition is valid for all circulation modes and also during the runt- ime Circ. run. after a draw-off detection. Note When Timer is selected, the days of the week (Mo …...
  • Page 15: Disinfection

    Disinfection Note In order to use the thermal disinfection, a circulation unit is required! The circulation pump has to be connected to the controller. The thermal disinfection function offers two possibilities to reduce germ contami- nation of the water inside the circulation circuit. In the Disinfection mode channel, the disinfection modes Hygiene or Decontamination can be selected.
  • Page 16: Miscellaneous Menu

    Miscellaneous menu In the Misc. menu, all basic parameters for the controller can be adjusted. Normal- Note ly, these settings have been made during commissioning. They can be subsequently When the Disinfection duration has elapsed but the required tempera- changed in this menu. ture has not been reached at the circulation sensor, the message ⚠...
  • Page 17: Manual Mode Menu

    Manual mode menu User code In the User code menu, a user code can be entered. Each number of the 4-digit In the Manual mode menu, the operating mode of both relays can be adjusted. code must be individually adjusted and confi rmed. After the last digit has been con- The adjustment channels are named after the pumps connected.
  • Page 18: Troubleshooting

    Troubleshooting If a malfunction occurs, a message will appear on the display of the controller. WARNING! Electric shock! Upon opening the housing, live parts are exposed! Î Always disconnect the device from power supply be- fore opening the housing! The controller is protected by a fuse. The fuse holder (which also holds the spare fuse) becomes accessible when the cover is removed.
  • Page 19 Pump noise can be heard, bubbling in the pipes. DHW heating does not work System vented? Controller in operation? Check the controller; Check the fuse of and the power supply to the Vent the system. controller. System vented? Vent the system. Draw-off amount is too small.
  • Page 20: Accessories

    Accessories Sensors and measuring instruments Interface adapters Temperature sensors VBus / USB interface adapter ® The product range includes high-precision platinum temperature sensors, flatscrew The VBus ® / USB interface adapter is the interface between the controller and a sensors, outdoor temperature sensors, indoor temperature sensors, cylindrical cli- personal computer.
  • Page 21: Index

    Index Main display .......................... 8 Accessories......................... 20 Mains connection ........................ 5 Balance values ........................10 Manual mode ........................17 Measured and display values ..................... 9 Circulation .......................... 12 Menu structure ........................8 Circulation flow rate calibration ................... 13 Miscellaneous ........................16 Commissioning menu ......................
  • Page 24 - they only represent use outside the copyright requires the approval of RESOL – Elektronische some examples. They can only be used at your own risk. No liability is assumed for Regelungen GmbH.