GEZE GC 402 WVS Installation Instructions Manual

GEZE GC 402 WVS Installation Instructions Manual

Wind- and rain sensor set
Table of Contents

Advertisement

Available languages

Available languages

GEZE
GC 401 RS
GC 402 WVS
DE
Wind- und Regensensor Set
GB
Wind- and Rain Sensor Set
DE
Montageanleitung
GB
Installation instructions
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GC 402 WVS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GEZE GC 402 WVS

  • Page 1 GEZE Montageanleitung Installation instructions GC 401 RS GC 402 WVS Wind- und Regensensor Set Wind- and Rain Sensor Set...
  • Page 2: Symbole Und Darstellungsmittel

    à des Herstellers voraus. Nur GEZE Originalteile für Reparaturarbeiten verwenden. à Eigenmächtige Veränderungen an der Anlage schließen eine Haftung von GEZE für daraus resultierende à Schäden aus. Die Gerätemontage und deren Anschluss darf nur durch eine Fachfirma nach den GEFAHR Vorschriften von VDE und des örtlichen EVUs vorgenommen werden.
  • Page 3: Technische Daten

    GC 401 RS , GC 402 WVS Produktbeschreibung Lieferumfang Windgeschwindigkeits- und Regensensor Set (Mat.-Nr. 140229) Regensensor (24 V DC/AC) mit Gerätekonsole GC 401 RS Windgeschwindigkeits-Sensor GC 402 WVS Klemmring Konsole (Aluminium) für Wand- oder Mastmontage Produktmerkmale Regensensor Windgeschwindigkeits-Sensor Anschluss Anschluss...
  • Page 4: Montage

    Montage GC 401 RS , GC 402 WVS Montage Die Sensoren sind an einer dem Wetter zugewandten Gebäudeseite zu montieren. Umliegende Gebäudeteile à sowie elektrische Geräte dürfen deren Funktion nicht beeinträchtigen. Die Konsole muss auch bei extremen Wetterverhältnissen (Sturm) sicheren Halt gewährleisten.
  • Page 5 GC 401 RS , GC 402 WVS Wartung, Pflege, Reparatur Montage von Wind- und Regensensor an Wand-/ Mastkonsole Kabel von Wind-/Regensensor (10) durch das Rohr des Wand-/Masthalters (7) führen. Schraube (3) in Klemmring (1) min. 15 mm einschrauben. ACHTUNG : Rohr (7) vorsichtig bis zum...
  • Page 6: Key To Symbols

    Warrenty claims require professional installation and service according to the guidelines of the manufacturer. à à Use only GEZE original parts for repair work. Unauthorised modifications of the system excludes GEZE from the liability for any resulting damage. à All electrial connections should be made by a properly electricain and connected in DANGER accordance with the appropriate standards of the country of installation.
  • Page 7: Scope Of Delivery

    Product description GC 401 RS , GC 402 WVS Scope of delivery Wind speed and Rain Sensor Set (Mat.-No.: 140229) Rain sensor (24 V DC/AC) with equipment bracket GC 401 RS Wind speed sensor GC 402 WVS Clamping Ring Bracket (aluminium) for pole or wall mounting...
  • Page 8 Mounting GC 401 RS , GC 402 WVS Mounting The sensors have to be mounted on the weather side of building. Surrounding buildings and electrical equip- à ment must not impair their function. The mounting bracket has to be fixed for extremely weather conditions.
  • Page 9 Maintenance, servicing, repairs GC 401 RS , GC 402 WVS Pole and wall mounting of wind speed and rain sensor Lead the cables (10) of wind and rain sensor by the tube (7) of bracket Turn the screw (3) min. 15 mm into clamp ring (1).
  • Page 10 GC 401 RS , GC 402 WVS Notizen / Notes:...
  • Page 12 Singapore 658065 Baltic States 107076 Moskau Blenheim Way Tel. +65-6846 1338 GEZE GmbH Baltic States o ce Tel. +7 (0) 49 55 89 90 52 Fradley Park Fax +65-6846 9353 Dzelzavas iela 120 S Fax +7 (0) 49 55 89 90 51 Lich eld E-Mail: gezesea@geze.com.sg...