Cisco PA-2CE1 Series Installation And Configuration Manual page 58

Channelized e1 port adapter
Table of Contents

Advertisement

Checking the Configuration
VIP2 in Cisco 7000 Series and Cisco 7500 Series Routers
Following is an example of the show controllers e1 command that shows the status of a PA-2CE1
installed in port adapter slot 1 on a VIP2 in interface processor slot 3:
Router# show controllers e1
E1 3/1/0 is up.
Applique type is Channelized E1 - unbalanced
No far end block errors detected
No alarms detected.
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (700 seconds elapsed):
Data in Interval 1:
Total Data (last 1 15 minute intervals):
E1 3/1/1 is up.
Applique type is Channelized E1 - unbalanced
No far end block errors detected
No alarms detected.
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (700 seconds elapsed):
Data in Interval 1:
Total Data (last 1 15 minute intervals):
Proceed to the next section, "Using the ping Command to Verify Network Connectivity" to check
network connectivity of the PA-2CE1 and switch or router.
PA-2CE1 Channelized E1 Port Adapter Installation and Configuration
4-22
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
10 Line Code Violations, 1 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
10 Line Code Violations, 1 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins,
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
10 Line Code Violations, 1 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
10 Line Code Violations, 1 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins,
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs