STANDBY MODES
STANDBY MODE
CONDITION
Standby Mode 1
Method A
(Power Button)
•
ECO mode : ON
•
Power mode: Switch from other Power Mode (Always ON, 12V Trigger,
Signal Sense) to Power Button
Method B
•
ECO mode : ON
•
Power mode: Currently at Power Button and unit at operating mode
Method A
Standby Mode 2
(12V Trigger)
•
ECO mode : ON
•
Rear panel 12V TRIGGER switch: ON
•
Power mode: Switch from other Power Mode (Power Button, Always
ON, Signal Sense) to 12V Trigger
Method B
•
ECO mode : ON
•
Rear panel 12V TRIGGER switch: ON
•
Power mode: Currently at 12V Trigger and unit at operating mode
Standby Mode 3
Method A
(Signal Sense)
•
ECO mode : ON
•
All Sources are powered down or no signal output
•
Power mode: Switch from other Power Mode (Power Button, Always
ON, 12V Trigger) to Signal Sense
Method B
•
ECO mode : ON
•
All Sources are powered down or no signal output
•
Power mode: Currently at Signal Sense and unit at operating mode
Method A
Network Standby Mode 1
(Power Button)
•
ECO mode : OFF
•
Power mode: Switch from other Power Mode (Always ON, 12V Trigger,
Signal Sense) to Power Button
Method B
•
ECO mode : OFF
•
Power mode: Currently at Power Button and unit at operating mode
Network Standby Mode 2
Method A
(12V Trigger)
•
ECO mode : OFF
•
Rear panel 12V TRIGGER switch: ON
•
Power mode: Switch from other Power Mode (Power Button, Always
ON, Signal Sense) to 12V Trigger
Method B
•
ECO mode : OFF
•
Rear panel 12V TRIGGER switch: ON
•
Power mode: Currently at 12V Trigger and unit at operating mode
Network Standby Mode 3
Method A
(Signal Sense)
•
ECO mode : OFF
•
All Sources are powered down or no signal output
•
Power mode: Switch from other Power Mode (Power Button, Always
ON, 12V Trigger) to Signal Sense
Method B
•
ECO mode : OFF
•
All Sources are powered down or no signal output
•
Power mode: Currently at Signal Sense and unit at operating mode
OPERATION
RESULT
•
Unit will immediately go to standby mode after the switch to Power
Button mode.
•
Unit will immediately go to standby mode when front panel Standby
button is pressed.
•
Unit will immediately go to standby mode after the switch to 12V
Trigger mode.
•
Unit will immediately go to standby mode when 12V TRIGGER source is
turned off.
•
Unit will immediately go to standby mode after the switch to Signal
Sense mode.
•
Unit will go to network standby mode after 20 minutes of no active
audio source input.
•
Unit will immediately go to standby mode after the switch to Power
Button mode.
•
Unit will immediately go to network standby mode when front panel
Standby button is pressed.
•
Unit will immediately go to network standby mode after the switch to
12V Trigger mode.
•
Unit will immediately go to network standby mode when 12V TRIGGER
source is turned off.
•
Unit will immediately go to standby mode after the switch to Signal
Sense mode.
•
Unit will go to network standby mode after 20 minutes of no active
audio source input.
13