Technical data
Battery under voltage
threshold
Battery type
Battery life
Operating frequency
HF transmission power
Transmission and
reception range
Supervision notification
Standards for intrusion
and panic button
devices
EU Directives
Certification authority
General
22 |
E N
2.4 V
'Flat battery' fault at < 2.4 V
If the voltage is below the lower threshold of 2.4 V, a fault report is
sent to the alarm control panel and the user is informed.
2 x AA alkaline batteries
Duracell Procell MN1500, Duracell Industrial ID1500,
Energizer E91
up to 3 years
868.6625 MHz narrow band
max. 10 mW
up to 1000 m range outdoors
approx. every 4 minutes
complies with EN 50131-2-2:2008
RED: 2014/53/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
WEEE: 2012/19/EU
ErP: 2009/125/EU
Low voltage: 2014/35/EU
General safety: 2001/95/EG
Telefication
This product must be installed by a qualified service engineer.