If zoning control was added during initial installation
of the S30 control system. Perform the following
steps:
1. Navigate through the various commissioning
screens until you reach Equipment Found
screen. Verify that a Zone Control icon is
present. If so, the system has detected the
equipment. Press continue to proceed.
NOTE: If zoning control is not listed, verify installation
of the damper control module and all wiring
connections. Make any corrections required
and run Re-Configure System feature again.
2. When the iHarmony Zoning screen appears,
select each zone listed to rename it if desired.
The system provides predefine names or a
custom name can be added. Press done when
completed and press continue to proceed.
NOTE: If a particular zone is missing from the list,
verify that the zone sensor wiring is correct
and that the zone address is set correctly on
zone sensor.
3. The Verify Airflow Per Zone screen will appear.
Make the requirement CFM adjustment for each
zone on this screen. When done, press continue
to proceed.

Rerunning Thermostat Commissioning

If zoning control was added to an existing S30
control system. Perform the following steps:
1. From the home screen, select the Menu Icon
2. Select Settings
3. Select Advanced Settings
4. Select View Dealer Control Center
5. Select Equipment
6. Select Reset
7. Select Re-Configure System. This will instruct
the thermostat to scan for new equipment.
8. Navigate through the various commissioning
screens until you reach Equipment Found
screen. Verify that a Zone Control icon is
present. If present, the system has detected the
equipment. Press continue to proceed.
NOTE: If zoning control is not listed, verify installation
of the damper control module and all wiring
connections. Make any corrections required
and run Re-Configure System feature again.
9. When the iHarmony Zoning screen appears,
select each zone listed to rename it if desired.
The system provides predefine names or a
custom name can be added. Press done when
completed and press continue to proceed.