Clock Setting; Checking The Clock; Varispeed Clocking; Clock Change Action - Tascam DM-3200 Owner's Manual

Digital mixing console
Hide thumbs Also See for DM-3200:
Table of Contents

Advertisement

3 – Connections : Clock setting

Clock setting

When the connections have been made to the DM-
3200, you must select a clock source. The master
clock source is also used to determine the sampling
frequency for the whole project.
Remember that the DM-3200 can act as a clock
source or clock master, but there must be only one
master clock source in your studio setup.
Press the
PROJECT
key until the
appears:

Figure 3.6: PROJECT CLOCK screen (high-speed)

Fs MODE
The first item to be selected is the use of
the high-speed or normal clock. When the lower
88.2K/96K
(high-speed) option is selected, many of the
and
legends on the screen change to
44.1K
48K
and
respectively. In addition, in high-speed
96K
mode, the digital inputs are also available, and the
number of available clock sources on the optional
AES/EBU interface card (if fitted) is reduced:
In both this and the normal speed clock screen, the
current clock status is displayed at the top of the
screen (as shown above).

Checking the clock

You can make a check of the
system by moving the cursor down to the bottom of
the screen and pressing the
44
TASCAM DM-3200 User's Manual
CLOCK
screen
88.2K
CHECK [START]
button.
After confirming that you want to do this, a popup
appears, informing you of the status of all potential
clock sources.

Figure 3.7: Checking the clock sources

Varispeed clocking

Note that the DM-3200 is
able to accept audio data and clock signals from
"varispeed" devices, provided the playback speed
and hence the sampling frequency is within 6% of the
nominal frequency.
Of course, when the out-of-normal clock is to be re-
transmitted to other devices, it depends on the imple-
mentation of the other devicse as to whether the
clock can successfully be accepted by them.

Clock change action

changed, you have an option to reboot and keep
(
) the existing mixer configuration (
KEEP
FIGURATION
), or to initialize the settings (
the DM-3200.
When you make the change to the clock, an appropri-
ate popup message appears, telling you what is about
to happen (either the mixer will reboot, or the data
will be initialized). Press
ENTER
operation or a cursor key to cancel it.
WARNING
Whichever option you select here, remember that
changing the clock source and/or frequency may pro-
duce "thumps" and noise which may cause damage to
your hearing and the monitoring system, etc. Turn
down the levels of all such equipment before making
the change to the clock settings.
When the clock is
MIXER CON-
INITIALIZE
)
to carry on with the

Hide quick links:

Advertisement

Table of Contents
loading