All manuals and user guides at all-guides.com EXES-6000 CP-63 INTERCOM SYSTEM TOA EXES-6OOO INTERCOM SYSTEM Central Processing Unit for Tie-line System CP-63 INSTALLATION HAND BOOK TOA ELECTRIC CO., LTD. KOBE, JAPAN 133-21-081-1...
All manuals and user guides at all-guides.com CONTENTS Page INTRODUCTION TO THE INSTALLATION MANUAL FOR EXES-6000 FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS TIE-LINE CONNECTION OF THE EXCHANGES WIRING FOR TIE-LINE CONNECTION OF THE EXCHANGES PART 1. OPERATING OF CP UNIT AND NO. 200 PROGRAMMING 1.
All manuals and user guides at all-guides.com INTRODUCTION TO THE INSTALLATION MANUAL FOR EXES-6000 This manual forms part of the Installation Manual for TOA INTER- This "Installation Handbook of CP-63" deals principally with (2) COM SYSTEM EXES-6000. Selection of functions and setting up of respective equipment.
All manuals and user guides at all-guides.com FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS Those functions of the CP-63 which require either the addition of specific units or processing in existing units are as mentioned below. Before installation and adjustment of equipment, make sure to check your system. (For Data Transmitting and Receiving units, refer to Part 2.
Page 5
All manuals and user guides at all-guides.com Example of Exchange Mounted on Intercom Cabinet Rack (For Tie-line System Including All-Call Paging and 7 Individual Zone Paging unit and one Data Transmitting unit) Exchange EX-620 (for 128 stations) Exchange EX-610 (for 64 stations) Central Processing Unit CP-63 Power Supply Unit DS-620 Power Switch...
All manuals and user guides at all-guides.com TIE-LINE CONNECTION OF THE EXCHANGES 1. Function of the Central Processing Unit CP-63 Exchange "A" Exchange "B" To make communications between exchanges possible in the EXES- Dial data 6000 system, the CP-63 and the Tie-line Interface Unit TI-62 are required in addition to the exchange EX-610 or the EX-620.
Page 7
All manuals and user guides at all-guides.com 3. Numbering schedule for stations and paging zones A. With personal number (Standard) Numbering for stations Numbering for paging zones Type of 7 zones Paging zone per exchange Model With exchange Without Paging paging All call Zone...
Page 8
All manuals and user guides at all-guides.com 6. The relationship between the PI unit and the LM unit Exchange "A" Exchange "B" <The case where the tie-line system consisting of 2 or 3 exchanges has an exchange without the PI unit> The case where it is necessary to make the paging call from the exchange without the PI unit to the other exchange (s).
All manuals and user guides at all-guides.com WIRING FOR TIE-LINE CONNECTION OF THE EXCHANGES Each exchange can be connected by means of a cable with a diameter of 0.65mm (25.6 mils.) for a distance of up to 2km (5600 ft). Regarding the tieline links which are not used, turn off the DIP switch of each unused tieline link inside the Tie-line Unit TI-62.
Page 10
All manuals and user guides at all-guides.com 4. The Example of connection of EX-620 exchange YR-801 must be connected to J15 for EX-620 exchange (for 128 stations), or to J7 for EX-610 exchange (for 64 station) EX-620 BX-620 EX-610 BX-610 "Exchange A"...
Page 11
All manuals and user guides at all-guides.com 5. The Example of connection of EX-620 exchange YR-810 must be connected to J15 for EX-620 exchange (for 128 stations), or to J7 for EX-610 exchange (for 64 station) "Exchange C" "Exchange A" "Exchange B"...
All manuals and user guides at all-guides.com PART 1. OPERATING OF CP UNIT AND NO. 200 PROGRAMMING 1. PRECAUTIONS FOR INSTALLATION OF CP-63 Please read following instructions carefully to ensure proper operation of the CP-63 1. Be careful about damage by static electricity as the CP-63 8.
2. INITIAL CP-63 SET UP All manuals and user guides at all-guides.com In the event of the tie-line system, programming has to be set up in every exchange. Make sure that you have turned off the AC power switch. 1. Connect Data Transmitting Unit (DT- Connect the exchange, terminal boards and stations.
All manuals and user guides at all-guides.com 3. TROUBLE SHOOTING Error ROM • RAM Chip No. 3-1 Check of ROM & NMOS-RAM - No calls on the system. 1. Put the 4 "LINK SELECT" switches of the HC upward (Link No. 15 Example SELECT) and switch on the AC power of the exchange.
Page 15
All manuals and user guides at all-guides.com 3-6 The order of Tie-line link usage The Tie-line Link Number which is used in calls between exchanges As Fig. 1 and Fig. 2 show, in the exchanges which make calls, the is not directly indicated, but you can possibly get it from the link DL Link Number corresponds with Tl Tie-line Link Number.
Page 16
All manuals and user guides at all-guides.com Reference for Connection Link Number between DL and Tl Link Exchange which calls Exchange which is called Tl Tie-line Link Number Tl Tie-line Tie-line 2 Tie-lines 3 Tie-lines Link Number Link Link No After power switch Fixed by Connection is on, Links are...
All manuals and user guides at all-guides.com 4. CP-63 DIP SWITCHES FOR FUNCTION SELECTION Functions Switch OFF Switch ON Activate Link Selection; Link No. 0 ~ 3 Not Activate Activate Link Selection; Link No. 4 ~ 7 Not Activate SW-A Link Selection;...
All manuals and user guides at all-guides.com 5. DIP SWITCH SELECTION AND STATION NO. 200 PROGRAMMING FOR EACH FUNCTION No. 200 Programming should be proceeded in the following manner. 1. Write down the required data in "8. Programming Data Table (Page 42 ~ 47)". 2.
All manuals and user guides at all-guides.com 6. FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMING A. Clearance at one time Func- Function Function tion Clearance of Function Function Registration on All Stations Clearance of Function by Function Group Group Code Confirmation Numbering schedules...
Page 20
All manuals and user guides at all-guides.com FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMING B. Programming of System Initially Function Function Function Remarks Operating for Programming Programmed Group Code Mode The following standard station numbering schedules of the exchanges A, B and C are obtainable.
Page 21
All manuals and user guides at all-guides.com FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMING C. Programming of each Function Func- Func- tion OPERATING FOR PROGRAMMING tion Function 1st Parameter 3rd Parameter 4th Parameter 2nd Parameter Group Code Executive Priority Station No.
All manuals and user guides at all-guides.com 7. STATION NO. 200 PROGRAMMING FOR EACH FUNCTION 7-1 EXECUTIVE PRIORITY (FUNCTION CODE 50) (HIGHEST PRIORITY) EXECUTIVE PRIORITY (HIGHEST PRIORITY) STEP 1 Touch Function Code New Registration? Executive Station No. Touch Executive Station No. Touch Confirmation tone New Registration finished?
All manuals and user guides at all-guides.com 7-2 CONTINUOUS CALLING TONE (FUNCTION CODE 51) CONTINUOUS CALLING TONE STEP 1 Touch Function Code New Registration? Continuously Called Station No. ON Touch Continuously Called Station No. Touch Confirmation tone New Registration finished? Release? Continuously Called Station No.
All manuals and user guides at all-guides.com 7-3 STATIONS ALLOWED ACCESS TO ALL CALL (FUNCTION CODE 52) STATIONS ALLOWED ACCESS TO ALL CALL STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No. Touch Confirmation tone New Registration finished? Release? Allowed Station No.
All manuals and user guides at all-guides.com 7-4 STATIONS ALLOWED ACCESS TO CONFERENCE (FUNCTION CODE 53) STATIONS ALLOWED ACCESS TO CONFERENCE STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No. Touch Confirmation tone New Registration finished? Release? Allowed Station No.
All manuals and user guides at all-guides.com 7-5 AUTOMATIC ACCESS TO PAGING (FUNCTION CODE 54) HANDSET SUBSTATIONS ALLOWED ACCESS TO PAGING STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No. Touch Confirmation tone New Registration finished? Release? Allowed Station No.
Page 27
All manuals and user guides at all-guides.com COMPLEMENTARY NOTES (1) Automatic Access to Paging (3) Single Digit Dialing and Automatic Access to Paging This function facilitates Paging / Paging response from a By programming "Single Digit Dialing" at any master station, a Substation TL-600S.
All manuals and user guides at all-guides.com 7-6 STATIONS ALLOWED ACCESS TO ONE-SHOT MAKE OUTPUT (FUNCTION CODE 56) STATION ALLOWED ACCESS TO ONE SHOT MAKE OUTPUT STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No. Touch Confirmation tone New Registration finished?
All manuals and user guides at all-guides.com 7-7 STATIONS ALLOWED ACCESS TO MAKE/BREAK OUTPUT (FUNCTION CODE 57) STATIONS ALLOWED ACCESS TO MAKE/BREAK OUTPUT STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No. Touch Confirmation tone New Registration finished? Release? Allowed Station No.
All manuals and user guides at all-guides.com 7-8 STATIONS ALLOWED ACCESS TO 8 SELECTABLE OR DECIMAL OUTPUT (FUNCTION CODE 58) STATIONS ALLOWED ACCESS TO 8 SELECTABLE OR DECIMAL OUTPUT STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No.
All manuals and user guides at all-guides.com 7-9 STATIONS ALLOWED ACCESS TO 4 DECIMAL DIGITS OUTPUT (FUNCTION CODE 59) STATIONS ALLOWED ACCESS TO 4 DECIMAL DIGITS OUTPUT STEP 1 Touch Function Code New Registration? Allowed Station No. Touch Allowed Station No. Touch Confirmation tone New Registration finished?
All manuals and user guides at all-guides.com 7-10 SECRETARY TRANSFER (FUNCTION CODE 60) SECRETARY TRANSFER Step 1 Touch Function Code New Registration? Executive Station No. Secretary Station No. Touch Executive Station No. Secretary Station No. Touch Confirmation tone New Registration finished? Release? Executive Station No.
All manuals and user guides at all-guides.com 7-11 MASTER/SUB RELATIONSHIP (FUNCTION CODE 61) MASTER/SUB RELATIONSHIP Step 1 Touch Function Code New Registration? Sub Station No. Master Station No. Touch Sub Station No. Master Station No. Touch Confirmation tone New Registration finished? Release? Sub Station No.
All manuals and user guides at all-guides.com 7-12 GROUP HUNTING (FUNCTION CODE 62) TRANSFERED STATION No. FOR GROUP HUNTING Step 1 Touch Function Code New Registration? Transfered Station No. Original Station No. Touch Original Station No. Transfered Station No. Touch Confirmation tone New Registration finished? Release?
All manuals and user guides at all-guides.com 7-13 PAGING ZONE (FUNCTION CODE 70) ESTABLISHMENT OF EACH PAGING ZONE Step 1 Touch Function Code Paging Zone No. 1st Station No. Last Station No. (00~21, 00~45) of the Zone of the Zone Touch Paging Zone No.
Page 36
All manuals and user guides at all-guides.com GROUP BLOCKING 1 ESTABLISHMENT OF EACH GROUP Step 1 Touch Function Code Group No. 1st Station No. Last Station No. of the Group (1 ~6) of the Group Touch 1st Station No. Group No. Last Station No.
All manuals and user guides at all-guides.com 7-15 CALLING PARTY INDICATION (LAMP TYPE) (FUNCTION CODE 72) Registration of station number(s) having indication panel. ESTABLISHMENT OF EACH GROUP Step 1 Touch Function Code Last Station No. Group No. 1 st Station No. of the Group of the Group (1 ~ 8)
All manuals and user guides at all-guides.com 7-16 GROUP BLOCKING 2 : ALLOWING CALLS AMONG GROUPS (FUNCTION CODE 81) GROUP BLOCKING 2 ALLOWING CALLS AMONG GROUPS Step 1 Touch Function Code New Registration? Calling Group Called Group No. (s) (1 ~8) (max. 7) No.
All manuals and user guides at all-guides.com 7-17 GROUP BLOCKING 3 : ALLOWING GROUP ACCESS TO PAGING (FUNCTION CODE 82) GROUP BLOCKING 3 ALLOWING ACCESS TO PAGING ZONES Step 1 Touch Function Code New Registration? Paging Group No. (S) Paging Zone (00~21,00~45) (1 ~ 6) (max.
All manuals and user guides at all-guides.com 7-18 PROGRAMMABLE STATION NUMBERING (FUNCTION CODE 90) A. Programming of Single Station Number PROGRAMMABLE STATION NUMBERING Step 1 Touch Function Code New Registration? Programmed Station No. Hardwired Station No. Touch Programmed Station No. Hardwired Station No.
Page 41
All manuals and user guides at all-guides.com B. Programming of Serial Station Numbers PROGRAMMABLE STATION NUMBERING Step 1 Touch Function Code New Registration? First Last First Last Hardwired Station No. Hardwired Station No. Programmed Station No. Programmed Station No. First Last First Last...
All manuals and user guides at all-guides.com 8. PROGRAMMING DATA TABLE INITIAL PROGRAMMING Note. (Mark *) The first station of each exchange becomes the Programming Station: Exchange "A" ......No. 200 (100) Exchange "B"...
All manuals and user guides at all-guides.com < PROGRAMMING DATA TABLE 1 > Function Table for the System Function Function Registered Function Note of Registration Initial programming Group code data Select the head number of stations A/B/C= in each exchange from among the 200/470/740 Numbering schedules followings:...
Page 44
All manuals and user guides at all-guides.com Executive Priority (Highest Priority) Continuous Calling Tone Stations Allowed Access to All Call Stations Allowed Access to Conference Automatic Access to Paging Stations Allowed Access to One Shot Output Stations Allowed Access to Make/Break Output Stations Allowed Access to 1/8 Select (or Decimal) Output Stations Allowed Access to 4...
Page 45
All manuals and user guides at all-guides.com For Tie-line Unit For Paging Unit (EX-610) Executive Priority (Highest Priority) Continuous Calling Tone Stations Allowed Access to All Call Stations Allowed Access to Conference Automatic Access to Paging Stations Allowed Access to One Shot Output Stations Allowed Access to Make/Break Output Stations Allowed Access to 1/8...
Page 46
All manuals and user guides at all-guides.com For Paging Unit For Tie-line Unit (EX-620) Executive Priority (Highest Priority) Continuous Calling Tone Stations Allowed Access to All Call Stations Allowed Access to Conference Automatic Access to Paging Stations Allowed Access to One Shot Output Stations Allowed Access to Make/Break Output Stations Allowed Access to 1/8...
All manuals and user guides at all-guides.com <PROGRAMMING DATA TABLE 5> Paging Zone Table Paging Zone First Station No. Last Station No. Department 08(16) 15(31) 09(17 ) 16(32) 10(18) 17(33 ) 11(19) 18(34 ) 12(20) 19(35) 20(36 ) 13(21) 14(22) 21(37) Station Numbers Table for Calling Party Indication (Lamp Type)
Page 48
All manuals and user guides at all-guides.com <PROGRAMMING DATA TABLE 7> Group Blocking for Paging Groups Paging Zone Paging Group No. Others Department All Call 8 (16 ) 9(17 ) 10(18 ) 11(19 ) 12(20) 13(21) 14(22) 15(31) 16(32) 17(33) 18(34) 19(35) 20(36)
Page 49
All manuals and user guides at all-guides.com Summary Table of Group Blocking (Function Code 71, 81, 82) and Paging Zone (Function Code 70) Note. indicates that registration is not necessary, indicates stations not belonging to any group. Stations in Each Paging Stations Zone...
All manuals and user guides at all-guides.com PART 2. FUNCTION SELECTION FOR DATA TRANSMITTING AND RECEIVING UNITS 9. SETTING OF CHANNEL SELECT SWITCH OF TRANSMITTING UNIT (DT-E11) AND WORD SELECT SWITCH OF RECEIVING UNIT (DR-B61) NOTE 1. Connect the DT-E11 and DR-B61 to Exchange correctly. (Refer necessary functions such as IN/OUT Annunciation, Calling Party to operation manuals of DT-E11 and DR-B61).
All manuals and user guides at all-guides.com 10. DIP SWITCH TABLE FOR DATA TRANSMITTING AND RECEIVING UNITS CHANNEL SELECT Switch WORD SELECT Switch — 50 —...
All manuals and user guides at all-guides.com 11. SYSTEM DIAGRAM OF DATA TRANSMITTING AND RECEIVING UNITS (When the exchanges are connected by means of tie-line.) Stations Stations Stations Tie-line Unit TI-62 Tie-line Unit TI-62 Tie-line Unit TI-62 <Terminal Board> (Terminal Board) (Terminal Board) YR-810 YR-810...
All manuals and user guides at all-guides.com 12. EXPLANATION OF DATA TRANSMITTING UNIT OUTPUT CHANNELS CHANNEL SELECTION APPLICATION FUNCTIONS DESCRIPTION Personel in and out registration can be accomplished at any Master sta- tion by using personal numbers. Max. IN/OUT Annunciation •...
All manuals and user guides at all-guides.com 13. EXPLANATION OF DATA RECEIVING UNIT OUTPUT DATA 13-1 Channel 0 (CH. 0) In/Out Annunciation (Dial Operation) (Relay Make) XXX: 000 ~ 499 (500 Contacts ) Personal Number Registration (Relay Break) Personal Number Cancellation CHANNEL SELECT Switch Each Relay Output shows last 3 digits (xxx) of Personal...
All manuals and user guides at all-guides.com 13-3 Channel 2 (CH. 2) Calling Party Indication (Lamp Type) (1) Each "Calling Station" or "Waiting Station" is shown by Each Lamp of Indication. Total Number of Station with Indications: 4 Stations (Groupsl/Channel [8 Stations (Groups)/2 Channels] Total Number of Calling Stations: Max.
All manuals and user guides at all-guides.com 13-4 Channel 3 (CH. 3) Calling Party Indication (Lamp Type) (2) Each "Calling Station" or "Waiting Station" is shown by Each Lamp of Indication. Total Number of Station with Indications: 4 Stations (Groupsl/Channel [8 Stations (Groups)/2 Channels] Total Number of Calling Stations: Max.
All manuals and user guides at all-guides.com Appendix. Instructions for building the CP-63 in the EXES-5000 1. The CPU-55/56 differ from the CP-62/63 in dial operation. Function CPU-55 CPU-56 CP-62 CP-63 Continuous Calling Tone One-touch Response 8 Selectable Make Output X: 1 ~ 9, Y: 0~ 7 X: 1 ~ 9, Y: 1 ~ 8, 0 (Clear) X: 1 ~ 9, Y: 1 ~ 8, 0 (Clear)