46
14.
Mute
(Command: k e)
Mutes/unmutes audio.
Transmission
[k][e][ ][Set ID][ ][Data][Cr]
Data
00: Mute on (Volume off)
01: Mute off (Volume on)
Acknowledgment
[e][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be available for all models.
15. Volume Control (Command: k f)
Adjusts the playback volume.
Transmission
[k][f][ ][Set ID][ ][Data][Cr]
Data
00-64: Volume 0-100
Acknowledgment
[f][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be available for all models.
16. Clock 1 (year/month/day) (Command: f a)
Sets the Clock 1 (year/month/day) values and Auto Time.
Transmission
1. [f][a][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
2. [f][a][ ][Set ID][ ][0][0][ ][Data1][Cr]
1. When setting Clock 1 (year/month/day)
Data 1 00-: 2010 -
Data 2 01-0C: January - December
Data 3 01-1F: 1-31
* The minimum and maximum values for Data1 differ depending on the
product's release year.
* Enter "fa [Set ID] ff" to view Clock 1 (year/month/day) settings.
2. When Setting Auto Time
Data 1 00:
Auto
01:
Manual
* To view the set value of the Auto time, enter "fa [Set ID] 00 ff" .
Acknowledgment
1. [a][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
2. [a][ ][Set ID][ ][OK/NG][0][0][Data1][x]
17. Clock 2 (Hour/Minute/Second) (Command: f x)
Sets the Clock 2 values (hour/minute/second).
Transmission
[f][x][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
Data 1 00-17: 00-23 hours
Data 2 00-3B: 00-59 minutes
Data 3 00-3B: 00-59 seconds
* Enter "fx [Set ID] ff" to view the Time 2 (hour/minute/second) settings.
* This feature is only available when Clock 1 (year/month/day) has been
set.
Acknowledgment
[x][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
18.
Daylight Saving Time
Sets Daylight Savings Time.
Transmission
[s][d][ ][Set ID][ ][Data1][ ][Data2][ ]
[Data3][ ] [Data4][ ][Data5][ ][Cr]
Data1 00: Off (Data2-5: FF)
01: Start Time
02: End Time
Data2 01~0C: January - December
Data3 01-06: Week 1 - 6
* The maximum value of [Data3] may vary depending on the date.
Data4 00-06: (Sunday - Saturday)
Data5 00-17: 00 - 23 hours
If you wish to read the start/end times,
enter FF for parameters [Data2] through [Data5].
(Example 1: sd 01 01 ff ff ff ff - Checks the start time.
Example 2: sd 01 02 ff ff ff ff - Checks the end time.)
* This feature only works when Clock 1 (year/month/day) and Clock 2
(hour/minute/second) have been set.
Acknowledgment
[d][ ][Set ID][ ][OK/NG][Data1][Data2]
[Data3][Data4][Data5][x]
* This feature may not be available for all models.
(Command: s d)

Hide quick links: