Download Print this page

IMER COMBI 200 VA Operating, Maintenance, Spare Parts Manual page 13

Sawing machine

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Repairs to the electrical installation must be performed exclusively by
specialised personnel. Use exclusively original IMER spare parts; modi-
ve is required.
Ensure that the contacts of the power plug and plug-switch assembly
As regards disposal of processing waste observe all current legislation
in the country of use.
Although the sawing machine has been manufactured fully in complian-
ce with current regulations, residual risks exist that cannot be eliminated
and involve the use of appropriate individual protection devices. Ade-
the behaviour to be followed.
NOISE RISK
Please be reminded that checking the use of IPDs is delegated to the
employer.
IMER INTERNATIONAL S.p.A.
COMBI 200 VA
-
The motor does not
start when the start
switch is pressed
Cooling water fails
to reach the blade
The blade does
not cut
* Operation to be carried out by an electrician
13
Trouble
Causes
Current does not reach
the supply line
The socket and plug
are not connected
properly
The differential switch
is off
The power cable from
the plug to the panel
is cut off
An electric wire inside
the motor terminal strip
is cut off
An electric wire inside
the panel is cut off
The start switch is
faulty
Low water level in tank Restore the water level
Current fails to reach
the pump
Pump failure
opposite direction to
that of rotation
Worn blade
GB
Remedies
Check the line *
Restore correct
connection
Turn the differential
switch on
Change the cable *
Restore the connection *
Change the switch *
Change the switch *
Check the pump
electrical supply *
Change the pump *
Remove the blade
and reposition it in the
direction shown on the
blade label
Change the blade