  • Page 1 Codian IP Gateway MSE 8350 Getting started...
  • Page 2 Codian IP Gateway MSE 8350 Getting started...
  • Page 3 TANDBERG. TANDBERG reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of TANDBERG to provide notification of such revision or change. TANDBERG provides this documentation without warranty, term, or condition of...
  • Page 4: Table Of Contents

    Table of contents General information ... 1 About the MSE 8350 IP GW blade ... 1 Port and LED location ... 1 LED behavior ... 2 Installing the IP GW blade ... 4 Step one: Install the IP GW blade into the MSE 8000 chassis ... 4 Step two: Connect to Ethernet Ports A and B ...
  • Page 5: General Information

    About the MSE 8350 IP GW blade The MSE 8350 IP GW blade fits into an MSE 8000 chassis. The IP GW blade is a voice and video gateway that allows calls to be made between pairs of IP endpoints that cannot normally connect directly to each other.
  • Page 6: Led Behavior

    LED behavior Table 1 describes the behavior of the LEDs. Table 1: IP GW blade LED behavior Compact Flash Activity Console Link Status Alarm System Load Color Indicates Flashing One of: green the IP GW blade is booting a configuration change has been made the configuration is being transferred by FTP Green...
  • Page 7 Table 1: IP GW blade LED behavior (continued) Ethernet Port Status, for each Ethernet port: Link Power Color Indicates Green The link has been negotiated as a full- duplex link Green Packets are being transmitted on this port Green The speed of the link from this port, which is either 10, 100, or 1000 Mbps Blue The IP GW blade is receiving power from...
  • Page 8: Installing The Ip Gw Blade

    Installing the IP GW blade Before installing the IP GW blade into the MSE 8000, read the Safety Information guide that accompanied the MSE 8000 chassis. Although blades are hot-swappable parts, you must only remove one blade at any time. Remove the power from the MSE 8000, if you need to remove more than one blade at a time.
  • Page 9 Using a No.1 Phillips screwdriver, tighten the screws in the retaining latches with a clockwise quarter turn. Figure 2: Inserting a blade into the chassis Figure 3: Closing the retaining latches on the front of a blade Installing the IP GW blade...
  • Page 10: Step Two: Connect To Ethernet Ports A And B

    Step two: Connect to Ethernet Ports A and B Connect an Ethernet cable from Ethernet Port A to an Ethernet switch (rather than a hub, to minimize interference from other devices on the network). The Ethernet port is a 10/100/1000 Mbps auto-sensing connection. Connect Port A to your local network and connect Port B to a second subnet or the internet depending on your application of the IP GW blade.
  • Page 11: Initial Configuration

    Initial configuration Step one: Configure Ethernet Ports A and B The default setting for the IP GW blade Ethernet ports is auto-sensing mode. If the switch ports to which you connect the IP GW blade are not also set to auto-sensing mode, then you need to configure the IP GW blade Ethernet ports to use the same speed and duplex mode.
  • Page 12: Configuring The Ip Gw Blade

    Configuring the IP GW blade Step one: Log in to the IP GW blade All administration of the IP GW blade is performed through the web interface. To log in to the web interface of the IP GW blade: Log in to the Supervisor’s web interface. Go to Hardware >...
  • Page 13: Step Three: Configure The Auto Attendant Menus (Optional)

    Step three: Configure the auto attendant menus (optional) Depending on the proposed configuration of your dial plan, and the settings for failed calls, callers can be connected to an auto attendant menu. The IP GW blade provides a highly flexible menu-creation feature. This enables you to create a menu (or a multi-layered menu structure) to provide end users with the options they require when they connect to the IP GW blade.
  • Page 14: Step Five: Add Endpoints And Call Groups (Optional)

    Step five: Add endpoints and call groups (optional) You can pre-configure a list of endpoints on the IP GW blade. For these endpoints, an operator or caller can simply choose the endpoint's name from an onscreen address book, rather than having to type in the endpoint's address when a caller wants to be connected to that endpoint.
  • Page 15: Checking For Updates

    Checking for updates It is a good idea to regularly check for updates to the main IP GW blade software image. This section describes how to upgrade the IP GW blade using the web interface. Note that you can also upgrade the IP GW blade using FTP; this can be more reliable if you are upgrading the device remotely.
  • Page 16: Troubleshooting And Technical Support Information

    Ensure that you provide all the details requested by the form to assist the technical support team in resolving your problem: the serial number and product model number (for example:MSE 8350) of the MSE blade...