TANDBERG D1320203 User Manual
TANDBERG D1320203 User Manual

TANDBERG D1320203 User Manual

Tandberg 3g gateway data port command interface user guide

Advertisement

Quick Links

TANDBERG 3G Gateway
Data port Command Interface User Guide
TANDBERG 3G Gateway
Data port Command Interface User Guide
Software version R 3
D1320203
TANDBERG
D1320203
1

Advertisement

Table of Contents
loading

Summary of Contents for TANDBERG D1320203

  • Page 1 TANDBERG 3G Gateway Data port Command Interface User Guide TANDBERG 3G Gateway Data port Command Interface User Guide Software version R 3 D1320203 TANDBERG D1320203...
  • Page 2: Table Of Contents

    CONNECTING TO THE DATA PORT COMMAND INTERFACE THROUGH THE RS-232 PORT. 4 2.1..4 ARDWARE AND ABLING 2.2..4 ROUBLESHOOTING CONNECTING TO THE DATA PORT COMMAND INTERFACE USING TELNET...6 THE TANDBERG 3G GATEWAY COMMANDS ...7 4.1..7 NTRODUCTION 4.1.1. Command format ...7 4.1.2. Command types...8 4.2.
  • Page 3: Introduction

    Data port Command Interface User Guide Introduction The TANDBERG 3G Gateway Data port Command Interface User Guide contains guidelines on how to use the textual command interface supported by the 3G Gateway system, further referred to as 3G Gateway. The Data port Command Interface can be accessed through Telnet via the LAN interface or through RS-232 by connecting a serial cable to the serial interface connector, referred to as the Data port (ref.
  • Page 4: Connecting To The Data Port Command Interface Through The Rs-232 Port

    PC or other device capable of serial communication). Pin no Signal NOTE! A straight through cable should be used between the TANDBERG 3G Gateway’s RS-232 port and the DTE. The figure below illustrates the recommended cable-wiring scheme for connecting the 3G Gateway to a PC through RS-232.
  • Page 5 TANDBERG 3G Gateway If communication cannot be established between the PC/terminal and the TANDBERG 3G Gateway’s Data port the following should be checked: • Verify that the serial cable is a straight through 9-pin to 9-pin cable • Confirm that the configuration of the PC/terminal’s serial RS-232 port is identical to the configuration of the TANDBERG 3G Gateway RS-232 port.
  • Page 6: Connecting To The Data Port Command Interface Using Telnet

    TANDBERG 3G Gateway Release R3.0 SW Release Date: 2007-03-13 NOTE! If the TANDBERG 3G Gateway has been protected with an IP password you will be prompted to enter this password before you can access the Data port Command Interface via Telnet.
  • Page 7: The Tandberg 3G Gateway Commands

    TANDBERG 3G Gateway The TANDBERG 3G Gateway Commands 4.1. Introduction Typing ‘?’ or ‘help’ when connected to the Data Port Command Interface will return a list of valid commands. The commands are used to control the functions of the 3G Gateway. A command may be followed by a set of parameters and sub-commands.
  • Page 8: Command Types

    TANDBERG 3G Gateway 4.1.2. Command types The commands can be divided into three major classes: • Parameter Configuration Commands, Xconf. • Status Commands, Xstat. • User Commands, Xcom. Parameter Configuration Commands are commands that set a system parameter to a specific value. E.g.: The command Xconf telnet mode: "on"...
  • Page 9: System Configuration Commands

    TANDBERG 3G Gateway 4.2.1. System Configuration Commands Command: Description: Dialplan Mapping of a call onto a service or another call. Dialplan Entry [1..64] Enabled: <On/Off> Dialplan Entry [1..64] Name: <S: 0, 30> Dialplan Entry [1..64] NetType: <All/H324m/H323/SIP> Dialplan Entry [1..64] Prefix: <S: 0, 128>...
  • Page 10 TANDBERG 3G Gateway distinguished: • • • • • • • Example of a DID Dialplan for mobile to SIP calls: Note: • • • *c xConfiguration Dialplan Entry 1 Enabled: On *c xConfiguration Dialplan Entry 1 Name: "H324m - SIP"...
  • Page 11 TANDBERG 3G Gateway *c xConfiguration Dialplan Entry 1 Prefix: "207947133" *c xConfiguration Dialplan Entry 1 Suffix: "" *c xConfiguration Dialplan Entry 1 ServiceId: 1 *c xConfiguration Dialplan Entry 1 Property 1 Name: "nettype" *c xConfiguration Dialplan Entry 1 Property 1 Value: "SIP"...
  • Page 12 TANDBERG 3G Gateway *c xConfiguration Dialplan Entry 2 Property 2 Name: "avmode" *c xConfiguration Dialplan Entry 2 Property 2 Value: "4" *c xConfiguration Dialplan Entry 2 Property 3 Name: "prefix" *c xConfiguration Dialplan Entry 2 Property 3 Value: "" *c xConfiguration Dialplan Entry 2 Property 4 Name: "suffix"...
  • Page 13 TANDBERG 3G Gateway *c xConfiguration Dialplan Entry 4 Prefix: "90370010" *c xConfiguration Dialplan Entry 4 Suffix: "" *c xConfiguration Dialplan Entry 4 ServiceId: 3 *c xConfiguration Dialplan Entry 4 Property 1 Name: "allowredirectep" *c xConfiguration Dialplan Entry 4 Property 1 Value: "0"...
  • Page 14 TANDBERG 3G Gateway *c xConfiguration Dialplan Entry 4 Property 14 Name: "entry5_label" *c xConfiguration Dialplan Entry 4 Property 14 Value: "Menu" *c xConfiguration Dialplan Entry 4 Property 15 Name: "entry5_nettype" *c xConfiguration Dialplan Entry 4 Property 15 Value: "H323" *c xConfiguration Dialplan Entry 4 Property 16 Name: "entry5_bnumber"...
  • Page 15 TANDBERG 3G Gateway • • • NOTE! Authentication Password is write only. Example of H323Gatekeeper feedback: Xconf H323Gatekeeper Authentication *c xConfiguration H323Gatekeeper Authentication Address: “abc.def.ghi.jkl” *c xConfiguration H323Gatekeeper Authentication Mode: Off *c xConfiguration H323Gatekeeper Authentication ID: "" Enables or disables access to HTTP services.
  • Page 16 TANDBERG 3G Gateway • • • • Example of IP Address feedback: *c xConfiguration IP Address: "127.0.0.1" Defines various ISDN protocol settings. ISDN ISDN OutgoingBearerCapability: <H324m/UDI> ISDN BRI SwitchType: <NI/ATT/Euro/Japan> ISDN PRI SwitchType: <NI/ATT/Euro/Japan> ISDN PRI Interface LowChannel: <1..31> ISDN NationalPrefix: <S: 0, 4>...
  • Page 17 *c xConfiguration SIP Interface Server Type: Auto *c xConfiguration SIP Interface Transport Default: UDP SNMP Configures the SNMP. Note! For more information about SNMP please read the TANDBERG SNMP application note. SNMP Mode < On/Off/ReadOnly/TrapsOnly > SNMP CommunityName: <S: 0, 16> SNMP SystemContact: <S: 0, 70>...
  • Page 18 ‘password’ in order to receive a response from the SNMP agent in the 3G Gateway. System Contact, Used to identify the system contact via SNMP tools such as HPOpenView or TANDBERG Management Suite System Location Used to identify system location via SNMP tools such as HPOpenView or TANDBERG Management Suite Host IP Addr identifies the IP-address of the SNMP manager.
  • Page 19 TANDBERG 3G Gateway Telnet Enables or disables telnet interface on the 3G Gateway Telnet Mode: <On/Off> Example of Telnet feedback: *c xConfiguration Telnet Mode: On D1320203 Data port Command Interface User Guide...
  • Page 20: General 3G Gateway Commands

    TANDBERG 3G Gateway 4.2.2. General 3G Gateway Commands Command: Description: ExternalManager This command sets the path and address of the TMS server. A message is sent to TMS when the 3G Gateway starts up to signal TMS that the 3G Gateway is ready.
  • Page 21 TANDBERG 3G Gateway OPC: <0 .. 16383> NetworkIndicator: <International0/International1/National0/National1> Law: <ALaw/ULaw> LinkSet [1 .. 2] Mode: <On/Off> LinkSet [1 .. 2] DPC: <0 .. 16383> LinkSet [1 .. 2] Link [1 .. 2] Mode: <On/Off> LinkSet [1 .. 2] Link [1 .. 2] Trunk: <1 .. 4>...
  • Page 22 TANDBERG 3G Gateway • Trunk CircuitIdentificationCode: The Circuit Identification Code is a unique identifier for a data time slot in a cable (trunk). In this case the CIC acts as base address and can be defined for each SS7 trunk and sets the first time-slot number of the respective SS7 trunk.
  • Page 23 TANDBERG 3G Gateway *c xConfiguration SS7 Trunk 1 Mode: Off *c xConfiguration SS7 Trunk 1 DPC: 0 *c xConfiguration SS7 Trunk 1 CircuitIdentificationCode: 0 *c xConfiguration SS7 Trunk 2 Mode: Off *c xConfiguration SS7 Trunk 2 DPC: 0 *c xConfiguration SS7 Trunk 2 CircuitIdentificationCode: 0...
  • Page 24 TANDBERG 3G Gateway *c xConfiguration SS7 Route 7 DPC: 0 *c xConfiguration SS7 Route 7 Priority: 0 *c xConfiguration SS7 Route 7 LinkSet: Off *c xConfiguration SS7 Route 8 DPC: 0 *c xConfiguration SS7 Route 8 Priority: 0 *c xConfiguration SS7 Route 8 LinkSet: Off...
  • Page 25: System Status Commands

    TANDBERG 3G Gateway 4.2.3. System Status Commands Command: Description: BRI [1..4] Displays the status of the BRI lines Parameters: • BRI [1..4] indicating the status of the different BRI lines Example of BRI feedback: *s BRI 1 (ready=True): Channel 1 (type=BChannel, status=Idle): /...
  • Page 26 TANDBERG 3G Gateway Name: "allowredirectivr" Value: "0" Property: Name: "DTMFInfoScreen" Value: "On" *s/end Disk Diaplays information regarding the internal harddrive Disk Status format: <Status > <CheckDisk> Parameters: • Status is either OK or ERROR • CheckDisk indicates whether a disk is present, mounted and can be read or written to.
  • Page 27 TANDBERG 3G Gateway Parameters: • Address, The IP address of the external management system • Protocol, the protocol used to access the management system • URL, the URL on the management system that should be opened by the 3G Gateway in case...
  • Page 28 TANDBERG 3G Gateway • Port, the gatekeeper port the 3G Gateway is connected with Example of H323Gatekeeper feedback: *s H323Gatekeeper (status=Registered): Address: "10.47.9.1" Port: 1719 *s/end Displays the IP configuration of the 3G Gateway Status format: <Address> <SubnetMask> <Gateway> <DNS:...
  • Page 29 TANDBERG 3G Gateway Returns the IP address of the NTP server. Status format: <Status> <Address> <Port> <Last Update> <Last Correction> Parameters: • Status, indicates whether the NTP server is active or not. • Address, the IP address of the NTP server.
  • Page 30 TANDBERG 3G Gateway Channel 10 (type=BChannel, status=Idle): / Channel 11 (type=BChannel, status=Idle): / Channel 12 (type=BChannel, status=Idle): / Channel 13 (type=BChannel, status=Idle): / Channel 14 (type=BChannel, status=Idle): / Channel 15 (type=BChannel, status=Idle): / Channel 16 (type=DChannel, status=NA): / Channel 17 (type=BChannel, status=Idle): /...
  • Page 31 • TemperatureCelcius, temperature of the main board in Celcius • TemperatureFahrenheit, temperature of the main board in Fahrenheit Example of SystemUnit feedback: *s SystemUnit: ProductType: "TANDBERG 3G Gateway" Uptime: 15123 Software: Version: "R3.0Beta2 (TEST SW)" Name: "test" ReleaseDate: "2007-03-21, 17:54"...
  • Page 32: Debug Commands

    TANDBERG 3G Gateway 4.2.4. Debug Commands Command: Desription: Enables a real-time log of Bonding, H.221 and H324m, ISDN, RTSP, IVider, and IVider Engine activity. Syslog Note! H323 and SIP logging is presented using the following command: tsh –a H323 (SIP).
  • Page 33: Special Commands

    TANDBERG 3G Gateway 4.2.5. Special (Xcommand) Commands Command: Description: Boot Reboots the system. Example: xCommand Boot *r Result (status=OK): / *r/end CUIL reboot request, restarting This command shows the presence and the status of the internal harddisk. CheckDisk Example: xCommand CheckDisk *r Result (status=OK): CheckDisk: "Disk present"...
  • Page 34 TANDBERG 3G Gateway • CallingParty: <S:0, 60> Service telephone number. • NetType: <All/H324m/H323/SIP> Nettype of the end point to be called. • CallType: <Tlph/Vtlph> Call type is either voice (Tlph), or voice and video (Vtlph). OK Result parameter: • Session ID: <S: 1.. 50>...
  • Page 35 TANDBERG 3G Gateway EraseDisk This command wipes all the data from the internal harddisk Example: xCommand EraseDisk *r Result (status=OK): *r/end Command used to deregister XML feedback over HTTP(S). FeedbackDeregister Parameters: • ID: <1 .. 3> ID for the registration to deregister.
  • Page 36 TANDBERG 3G Gateway *r Result (status=OK): ID: 2 *r/end OptionKeyAdd Command used to set new option keys. Parameters: • Key(r): <S: 0, 90> option key NOTE! Always reboot the system after adding option keys, for the option key to take effect.
  • Page 37 TANDBERG 3G Gateway *r Result (status=OK): / *r/end D1320203 Data port Command Interface User Guide...
  • Page 38: Commands

    TANDBERG 3G Gateway General User Commands Shows following system information: About Software version: R3.0 Portions of this software are licensed under 3rd party licenses. See the CD accompanying this product for details. Help or ? Displays the help menu. help...
  • Page 39 TANDBERG 3G Gateway (note: deregistration with index=0 will deregister all registered expressions) Examples: "xfeedback register status/call" - to monitor call changes "xfeedback register status/call--" - to monitor only call state changes "xfeedback register configuration" - to monitor all configuration changes...

Table of Contents