G2 1 Introduction The TANDBERG Gateway is designed to connect up to 8 videoconferencing calls and 8 telephone calls simultaneously between ISDN and IP Networks. The TANDBERG Gateway supports the ITU-T H.320 standard and a combination of H.221 and BONDING for communication on up to 30 ISDN B-channels as well as ITU-T H.323 v.4...
• Interactive Voice Response (IVR) • Direct Inward Dialing (DID) 2 Product Description The TANDBERG Gateway is built on a standard 19-inch rack mounted chassis of only 1U in height. 2.1 Software In the standard version, the TANDBERG Gateway supports up to 2 Mbps bandwidth on ISDN.
2 Mbps 4.1.1 Multiple Calls The TANDBERG Gateway may run 8 separate simultaneous videocalls and 8 phone calls. Please refer to the Capacity section for more information on available resources. 2 Only Ethernet port no. 1 is used in software version G2.
G2 4.1.2 PRI E1/T1 ISDN 4.1.2.1 ISDN number plan The TANDBERG Gateway’s PRI lines may use one or more numbers for dial in. If more than one number is used, the numbers must be consecutive. 4.1.2.2 PRI Trunk Grouping When using more than one PRI line, the same properties for PRI 1 can be used for all PRI's by defining them all as a trunk group.
Page 8
RING RX RING TX TIP TX NOTE: TANDBERG recommends always using category 5 cabling. PRI T1 (US only): Network Service Facility (NSF) can be configured as blank/no value (i.e. NSF not used – default) or any value between 0 and 31, to describe the service facility on the PRI/T1 line.
The H.323 aliases must be a portion of the ISDN number plus a prefix. Example: The TANDBERG Gateway is configured to use 4 digits of the ISDN Number, and 9 as the H.323 prefix: An endpoint dials the ISDN number 67117780 The TANDBERG Gateway transfers the call to the H.323 Alias 97780...
ISDN number, the call is transferred through the gateway, to the remote site on ISDN. The service defines the type of call (telephone/video) and bandwidth for the connection. It is possible to define up to 20 different services on the TANDBERG Gateway. The TANDBERG Gateway have two default services: Service Prefix ‘0’...
Cost- tells router to minimized cost Off- Turns TOS off 4.1.5.1.4 Resource-Reservation Protocol (RSVP) RSVP is a protocol that allows the TANDBERG Gateway to request the network to reserve the bandwidth needed for the IP meeting. 4.1.5.2 IP adaptive bandwidth management •...
Ping Ping is used to see if the TANDBERG Gateway is able to reach a specific IP- address, using a mechanism in IP called ICMP. If the TANDBERG Gateway is unable to register to its gatekeeper, or if it is unable to dial a specific endpoint, one can use ping to see if there is at least an IP-route to the gatekeeper or to the endpoint.
Range 2326—2837 4.1.5.8 IP packet sizes Audio The TANDBERG Gateway can receive up to 60 ms of audio in each packet. The TANDBERG Gateway is sending 20 ms of audio in each packet, thus: • G.711 – 160 bytes per packet •...
IPLR is a special algorithm developed at TANDBERG that will make efforts to reconstruct the lost packets and reduce the visual effects caused by packet losses. • If the TANDBERG Gateway experiences packet loss from an endpoint, it will ask the endpoint to handle packet loss. This requires Intelligent Packet Loss Recovery functionality on the endpoint.
TANDBERG Gateway’s transmitted framing info. Typically, this may be a broken connector in the TX part of the TANDBERG Gateway PRI cable. This could also indicate weak or noisy signal in the TX part of the TANDBERG Gateway PRI cable.
2 Mbps via ISDN networks. ICM is a highly sophisticated feature provided by the TANDBERG Gateway that e.g. makes the connection between two sites more reliable and safe. If the ISDN network drops channels...
(Users will be prevented from setting up calls that exceeds this limit). Example of call weight calculation: If the TANDBERG Gateway has made 1 encrypted call at 768kbps and two unencrypted calls at 384kbps the calculation will be: 222 + 2(92) = 222 + 184 = 406 Since 406 is less than 845, this will be OK.
*) Limited by the maximum capacity 7680 kbps, see rule II a) above. 4.1.9 Secure Conference (Encryption) The TANDBERG Gateway has built-in encryption of audio, video and data for both H.323 (based on ITU standard H.235) and H.320 (based on ITU standard H.233 and H.234).
(and the conference is set up for encryption mode of operation). Encryption is supported for meetings up to 768 kbps and for the TANDBERG feature DuoVideo. Note: For an encrypted call, the endpoints must support encryption (AES or DES).
1 channel from PRI 1 and build up the channels starting from the 'bottom' of the last PRI in use. This will ensure that the TANDBERG Gateway always have available channels on the first PRI number (which normally should be the TANDBERG Gateway 's main number).
Data Interfaces 1 x Data port, RS-232 (9-pin D-sub), Up to 115200 Baud for Data & Control The RS232 port on the TANDBERG Gateway is implemented as Digital Circuit Terminating Equipment (DCE). The connectors used are female 9-pin D-subs and the pin-out is shown in table below.
Technical Description of with software version G2 4.4 Video Features The TANDBERG Gateway supports the ITU video standards H.261, H.263, H.263+ and H.264. 4.4.1 Optimised Video Compression The ITU standard H.264 provides: • Optimised compression and decompression of video at lower bandwidths.
Duo Video, the TANDBERG Gateway will open Duo Video towards the other video site if capable of receiving it. If the other site requests for Duo Video the TANDBERG Gateway will automatically transmit this site’s Duo Video to the first site.
G2 4.5 Audio Features 4.5.1 Custom Sounds The TANDBERG Gateway has a variety of sounds that may be changed by storing new files on the FTP file system of the TANDBERG Gateway. Ref. Ch.5.2 for details. 4.5.1.1.1 Gateway Welcome When endpoints are entering a conference, they will be greeted with a default welcome sound.
Technical Description of with software version G2 4.6 System Management TANDBERG provides a comprehensive set of management tools, and is committed to the use of standards-based tools. The TANDBERG Gateway can be managed in many ways: The internal web server allows for remote control of the TANDBERG Gateway using a...
- for details) • A Telnet client (please see ‘TANDBERG Gateway API’- document D13202 - for details) • A terminal emulator for the RS232 port (please see ‘TANDBERG Gateway API’ - document D13202 - for details) 4.6.3 Protocols Supported TCP/UDP/IP -...
Windows operating system), it is possible to upload the new software release to the TANDBERG Gateway. The software file is in binary format in order to decrease upload time. All settings of the TANDBERG Gateway will be restored after a software upgrade.
To enable HTTPS, use the API command services https on. The HTTPS server will then be activated at next restart. If the TANDBERG Gateway’s HTTP service also is activated, the user will automatically be redirected to HTTPS. If HTTP is de-activated, you will have to specify HTTPS. (In the latter case https://10.0.5.203...
There is no router inside the system that can route between the ISDN side and the IP side of the TANDBERG Gateway. This means it is not possible to get access to the Ethernet port via an ISDN conference. However, if wanted the following services may be disabled/enabled (with API commands): •...
TANDBERG Gateway Technical Description of with software version G2 4.6.6 Layer 4 ports used by the system The following TCP and UDP ports are relevant for the TANDBERG Gateway. Function Port Type Direction Gatekeeper RAS 1719 ⇔ Gatekeeper Discovery 224.0.1.41:1718 ⇔...
5 Miscellaneous features 5.1 Phone book The TANDBERG Gateway can store up to 100 numbers in the phonebook. The phonebook may be edited through the web interface or by editing the dir.prm file, stored on file system of the TANDBERG Gateway (FTP). It also interacts with the Phone book features in TANDBERG Management Suite.
Page 32
TANDBERG Gateway Technical Description of with software version G2 Directory - dir.prm This file contains the directory/phonebook of the TANDBERG Gateway. D13192 Rev. 02...
Through people’s use of TANDBERG’s products, the environment will benefit from less use of polluting transport. • TANDBERG’s wide use of the concepts of outsourcing makes the company itself a company with a low rate of emissions and effects on the environment.
BABT and NEMKO. According to their Follow-Up Inspection Scheme, these agencies also perform production inspections at a regular basis, for all production of TANDBERG’s equipment. The test reports and certificates issued by the approval agencies show that the TANDBERG Gateway complies with the following standards. 7.1 Connection of Tele-Terminal Equipment TBR 4 •...
UL. For NEBS compliance, the product should be installed in the following manner: Use the enclosed rack brackets marked "NEBS". There should be a clearance of 9.1cm between the product and any other product mounted in the rack. D13192 Rev. 02...
• The Useful Life Cycle for the TANDBERG Gateway is in excess of 6 years. • TANDBERG is in a position to identify batches of products with possibly less reliability than stated above ('product tracking') and will in such an event inform their customers.
17.4 in Depth 31.8 cm 12.5 in 5.15 kg 11.3 lbs Weight The TANDBERG Gateway is a standard 19 inch rack mountable with 1U height. Standard cables for Part no. Length TANDBERG Gateway PRI cables (4) 111890 M1,M2,M3,M4 5.0 m 16.7 ft...
• 10% to 90 % Relative Humidity (RH) 9.4 Storage and Transport Temperature • -20° C to 60° C (-4° F to 140° F) at RH 10-90 % (non-condensing) 9.5 System Power Consumption • Maximum power consumption for TANDBERG Gateway is 90 W. D13192 Rev. 02...
TCP/IP,DHCP,SSL,ARP,FTP,Telnet,HTTP, HTTPS DiffServ SNMP Enterprise Management IP Precedence XML/SOAP Embedded WEB server RSVP Support for TANDBERG Management Suite IPLR TF 10/100Mbit full/half duplex (manual or auto detect selection) Other Supported ITU Standards H.320, BONDING (ISO 13871), H.231, H.243, H.221, H.242, H.245...
Page 40
Storage and Transport Temperature: Management using TANDBERG Management Suite -20° C to 60° C (-4° F to 140° F) at RH 10-90 % Call scheduling via TANDBERG Scheduler and (non-condensing) TANDBERG Management Suite (Optional) Physical Dimensions Embedded WEB server...