Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the inluence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

The itting must be installed, lushed and tested after the
valid norms!
Thermostatic mixer in conjunction with
combination boilers
If itting a hand shower remove the water limiter from
the shower.
Thermostatic mixer Shower: When using the Ecostat
with combination boilers, the Ecostop safety set
„95771000" has to be removed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
anti-pollution function
6
English
Symbol description
max. 1 MPa
0,1 – 0,5MPa
1,6MPa
max. 80°C
65°C
Do not use silicone containing acetic acid!
Safety Function (see page 61)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Adjustment (see page 63)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output difers from the
temperature set on the thermostat.
ECOSTOP (see page 64)
Maintenance (see page 65)
To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN EN
1717 in accordance with national or re-
gional regulations (at least once a year).
Operation (see page 67)