Appliance; General Information; Device Configuration; Configuration Using Tango-Utilities - SINUS Tango Plus User Manual

Sound level meter
Hide thumbs Also See for Tango Plus:
Table of Contents

Advertisement

2 Appliance

2.1 General information

Tango_Plus offers different operating modes:
OFF The device is off and no measurements can be performed. Only the clock is running inside.
Stop The device is running. The L
the circle symbol
Run The device is on and measuring (
stored (
is blinking). You may read the instantaneous measurement values on the display and move
between the values using the Up/Down keys.
Pause A running measurement is paused (
can be stopped or proceeded any time.
Display Description
The device is in Pause-Mode. The measurement has been paused and the measuring time has been stopped.
Data recording is active. The measured data will be stored in Run-Mode.
The device is in Run-Mode (Symbol blinks). The measurement has been started. If data recording is active, the
measured data are stored. If data recording is inactive, no data will be stored.
Table 2.1: Display of run modes
2.2 Device configuration
You may configure the device via PC using the software Tango-Utilities or manually.
2.2.1 Configuration using Tango-Utilities
For configuring the device via PC, you have to install the TANGO Driver and Tango-Utilities software first
(section 1.5). Possible settings in Tango-Utilities are adjusted in the Setup tab. In the column Display
use the check boxes to enable individual values and comboboxes to set the graphic refresh rate for display.
Several values offer optional parameters, which you may set in the column Options. By the buttons
and
you may open a configuration from the PC or save the current one to it. The same can be done
Save
by using the menu points File
current configuration is transmitted to Tango_Plus by clicking on
In the column Storage the correspondig storage conditions are adjusted. The storage can be turned off,
limited to one finish result or done in regular intervals. For the interval time span several values are provided
62 5
60
from
ms up to
a finish result over the whole measurement time is calculated and stored additionally. This would always be
saved, even if the intervall storage would have been aborted because of full memory. In this case the record
symbol
would stop blinking.
NOTICE!
If Synchronisation is enabled, the interval storage will be synchronised with the full hours of day time. So
every full hour the current interval is closed and a new one is started. The clock is set every time, when
connecting Tango_Plus to Tango-Utilities.
Manual Tango_Plus
2 APPLIANCE
and the L
AF
is displayed.
is blinking). If data recording has been activated, data will be
"'Open Configuration"' and File
min depending on the measurement value. Even if the interval storage is selected
For the interval storage of the percentiles only the same interval time span
can be selected.
are measured and displayed. If Record mode is enabled,
CF
is displayed) and so the measuring time. The measurement
.
Apply
12 of 30
"'Save Configuration As"'. The
SINUS Messtechnik GmbH
Open