Power Budget; Grounding - Avaya Secure Router 4134 Installation Manual

Chassis
Hide thumbs Also See for Secure Router 4134:
Table of Contents

Advertisement

Power supply
250 W DC

Power budget

The power budget for each module or module position in the Secure Router 4134 is shown in
the following table.
Table 15: Power budget for modules
Module
Fan tray
Main board
VPN internal module 7.0
Small Module
Medium Module
Total system budget
Available power from
power supply

Grounding

The Secure Router 4134 ships with a grounding lug. You must connect your ground wire to
the lug and attach the lug to the chassis in the upper right-hand corner of the front panel (as
shown in the following figure). For more detailed instructions on grounding the chassis, see
Installing the terminal lug on the Secure Router 4134
end of the ground wire to the most convenient site ground point for your installation. Use a
maximum of 8 AWG grounding cable for the Secure Router 4134.
Installation — Chassis
Input
-36 to -72 V DC
+12 V DC at 250
Watts (20.83 Amp at
nominal voltage)
Maximum module
power (W)
12.0
1
40.0
1
1
8.0
4
45.0
3
241.0
250
Output to router
components
from the +12 V DC
output)
N/A
Quantity
12.0
40.0
7.0
32.0
135.0
on page 42. You must attach the other
Power and grounding
PoE output
Power (W)
August 2013
51

Advertisement

Table of Contents
loading

Table of Contents