Download Print this page
Keysight Technologies Truevolt Series Security Features And Volatility Documentation

Keysight Technologies Truevolt Series Security Features And Volatility Documentation

Advertisement

Security Features and Volatility Documentation
Keysight Technologies, Inc.
Model Numbers:
34460A
34461A
34465A
34470A
Product Family:
Truevolt Series of Digital Multimeters
5991-1950EN
Revision 2.0
January, 2015
© Keysight Technologies, Inc. 2013 - 2015
Page 1 of 17

Advertisement

loading

Summary of Contents for Keysight Technologies Truevolt Series

  • Page 1 Security Features and Volatility Documentation Keysight Technologies, Inc. Model Numbers: 34460A 34461A 34465A 34470A Product Family: Truevolt Series of Digital Multimeters 5991-1950EN Revision 2.0 January, 2015 © Keysight Technologies, Inc. 2013 - 2015 Page 1 of 17...
  • Page 2 Page 2 of 17...
  • Page 3: Table Of Contents

    Contents Introduction ........................4 Contacting Keysight Sales and Service Offices ............4 Product Declassification and Security ................. 4 Terms and Definitions ....................5 Instrument Memory and Volatility Information ............6 Memory Clearing, Sanitization and/or Removal Procedures ........11 User and Remote Interface Security Measures ............13 Procedure for Declassifying a Faulty Instrument ............
  • Page 4: Introduction

    Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Introduction This document describes instrument security features and the steps to declassify an instrument through memory sanitization or removal. For additional information please go to www.keysight.com/find/security...
  • Page 5: Terms And Definitions

    Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Terms and Definitions Clearing As defined in Section 8-301a of DoD 5220.22-M, “National Industrial Security Program Operating Manual (NISPOM)”, clearing is the process of eradicating the data on media before reusing the media so that the data can no longer be retrieved using the standard interfaces on the instrument.
  • Page 6: Instrument Memory And Volatility Information

    Performing an instrument sanitization requires the instrument Security option (SEC) to be installed. Please refer to the Truevolt Series Operating and Service Guide for more information on available options. Summary of instrument memory - base instrument...
  • Page 7 Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Location in Memory Type Data Input Sanitization Purpose/Contents Instrument and and Size Method Procedure Remarks Front panel microprocessor Front panel Front panel Factory...
  • Page 8 Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Location in Memory Type Data Input Sanitization Purpose/Contents Instrument and and Size Method Procedure Remarks Front panel U201 Main processor Temporary Operating 1822-4268...
  • Page 9 Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Location in Memory Type Data Input Sanitization Purpose/Contents Instrument and and Size Method Procedure Remarks Main board U901 N/A, contains Measurement Processor execution...
  • Page 10 Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Summary of instrument memory: 34460A-GPB, 34461A-GPB, 34465A-GPB, 34470A-GPB, 3446GPBU Location in Memory Type Data Input Sanitization Purpose/Contents Instrument and and Size Method Procedure...
  • Page 11: Memory Clearing, Sanitization And/Or Removal Procedures

    Performing an instrument sanitization requires the instrument Security option (SEC) to be installed. Please refer to the Truevolt Series Operating and Service Guide for more information on available options.
  • Page 12 See the Truevolt Series Operating and Service Guide for more information. Memory sanitization Performing an instrument sanitization requires the instrument Security option (SEC) to be installed. Please refer to the Truevolt Series Operating and Service Guide for more information on available options. ***********...
  • Page 13: User And Remote Interface Security Measures

    With the instrument Security option, modifying these settings requires the instrument password. The secure count will increment when a remote interface is disabled or enabled. See the Truevolt Series Operating and Service Guide for more information. Page 13 of 17...
  • Page 14 Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A The LAN port provides the following services, which can be selectively disabled: a) LAN b) VXI-11 c) Sockets d) Telnet e) Web f) mDNS...
  • Page 15 To disable the display on the remote interface, send: DISP OFF Note: pressing Local will enable the display again. The display is enabled when power is cycled. See the Truevolt Series Operating and Service Guide for more information. How to disable the Front Panel during remote operation To programmatically lock out all front panel operation and remote access over the current interface, use the SYSTem:LOCK command.
  • Page 16 Product Declassification and Security Product Name: Truevolt Series of Digital Multimeters Model Numbers: 34460A, 34461A, 34465A, 34470A Calibration Regulation The instrument requires a password to unsecure the instrument before calibration. The instrument’s calibration count will increment with each successful calibration step.
  • Page 17: Procedure For Declassifying A Faulty Instrument

    (U203), and destroy it using a DSS/NISPOM approved destruction method Refer to the Truevolt Series Operating and Service Guide procedures for removing the front panel printed circuit assembly. Send the instrument to a Keysight repair facility. If the unit has option SEC and is still under warranty, the repair facility will replace the front panel printed circuit assembly.