In-Band Access

You can access the management agent in the switch from anywhere within the attached
network using Telnet, a Web browser, or other network management software tools.
However, you must first configure the switch with a valid IP address, subnet mask, and
default gateway. If you have trouble establishing a link to the management agent, check to
see if you have a valid network connection. Then verify that you entered the correct IP
address. Also, be sure the port through which you are connecting to the switch has not been
disabled. If it has not been disabled, then check the network cabling that runs between your
remote location and the switch.

Replacing the Power Supply

CAUTION
 When installing a new PSU, make sure it has the same airflow direction as the
fan modules and the other power supply.
For switches that only using a single power supply, removing the power supply
will cause the switch to automatically shut down.
The PSUs can be replaced without the use of special tools. Before replacing any of the PSUs,
verify the status of the PSU to determine if there is a need for replacement.
NOTE:
In the event of a power supply failure, you can replace the defective unit without powering
down the system, provided the other power supply is operational.
To replace the power supply unit:
1
Disconnect the AC power cord of the PSU that you want to remove.
2
Press the plug retainer and then pull the handle to slide the PSU away from the chassis.
NOTE:
Take note of the part number of the removed PSU. When you order a replacement PSU,
make sure that the part number of the new PSU is the same as the part number of the
removed PSU.
3
Ensure the power supply unit is correctly oriented, then install the new PSU into the
chassis until it is firmly seated.
4
Connect the AC power cord to power on the switch.
NETGEAR M4500 Series Switches Hardware Installation Guide 32