Download Print this page

Advertisement

Quick Links

Translation of the original short instruction
XL3000flex
Leak detector
Catalog No.
520-200
From software version
V2.81 (Operating unit)
jima83en1-02-(1910)

Advertisement

loading

Summary of Contents for Inficon XL3000flex

  • Page 1 Translation of the original short instruction XL3000flex Leak detector Catalog No. 520-200 From software version jima83en1-02-(1910) V2.81 (Operating unit)
  • Page 2 INFICON GmbH Bonner Strasse 498 50968 Cologne, Germany...
  • Page 3: Table Of Contents

    INFICON Table of Contents Table of Contents 1 Warnings ................................ 4 2 Safety ................................ 5 3 Short instruction.............................. 6 4 Description................................ 7 5 Settings................................ 11 XL3000flex-short-instruction-jima83en1-02-(1910)
  • Page 4: Warnings

    Imminent hazard resulting in death or serious injuries WARNING Hazardous situation resulting in potential death or serious injuries CAUTION Hazardous situation resulting in minor injuries NOTICE Hazardous situation resulting in damage to property or the environment 4 / 14 XL3000flex-short-instruction-jima83en1-02-(1910)
  • Page 5: Safety

    To ensure the safe use of the detector, please also read the operating instructions, which include further important information. The operating instructions can be found either on the USB memory stick or on the INFICON website. The USB memory stick is included in the shipment.
  • Page 6: Short Instruction

    3 Short instruction Intended use The XL3000flex is a helium or hydrogen leak detector for sniffing detection. With the device you locate and quantify leaks on test objects. A test object always contains gas under overpressure. Check the exterior of the test objects for escaping gas using a sniffer line (sniffing method).
  • Page 7: Description

    INFICON Description | 4 4 Description Scope of delivery Item Quantity XL3000flex USB stick (instruction manuals and short instructions in all available languages) Filter set for fans Set of fuses Power supply cable US Power supply cable UK Power supply cable JP...
  • Page 8 Connection for USB stick Area for fixing a holder for the Reset button, can be triggered by sniffer line key PIN Speaker Status LED. A permanently lit status LED shows that the sniffer line is supplied with voltage. 8 / 14 XL3000flex-short-instruction-jima83en1-02-(1910)
  • Page 9 IO1000 or the bus module, optional) Device power ON/OFF switch Connection "TL" for connection cable to calibration adapter for calibration leaks Electrical fuse Connection “LD“ for the data cable of the I/O module or bus module XL3000flex-short-instruction-jima83en1-02-(1910) 9 / 14...
  • Page 10: Description

    2. Push the sniffer line plug into the socket on the device until it locks into place. The plug may no longer be easy to move. Switching the device on ► Switch on the XL3000flex using the power switch on the back of the device ð The system is starting automatically ð...
  • Page 11: Settings

    Selecting the leak rate unit in the display for vacuum or sniffing mbar l/s (factory setting) Pa m3/s atm cc/s Torr l/s oz/yr Control unit Main Menu > Display > Units (Display) > Leak Rate Unit SNIF LD protocol Command 396 (sniffing) ASCII protocol Command *CONFig:UNIT:SNDisplay XL3000flex-short-instruction-jima83en1-02-(1910) 11 / 14...
  • Page 12: Short Instruction

    (Hydrogen, forming gas) He or deuterated hydrogen (HD) He (Helium) (factory setting) Control unit Main menu > Settings > Mass LD protocol Command 506 with value 2 (3, 4) ASCII protocol Command *CONFig:MASS 2 (3, 4) 12 / 14 XL3000flex-short-instruction-jima83en1-02-(1910)